7. Connections
Circuit
No.
board
23
K2
24
+
25
A+
26
K1
27
A-
28
-
7.1 Connecting with SmartRelay
32 / 140
Explanation
AUX relay: Potential-free contact (NO). Contact is
connected with K1 (number 26) if coil is connected
to power.
Equipped with a detachable bridge to + (number 24)
ex works.
V
. Connection for power supply.
IN
Equipped with a detachable bridge to K2 (number
23) ex works.
AUX relay: Coil's plus connection. AUX relay activ-
ates if coil is connected to power.
Equipped with a detachable bridge to K1 (number
26) ex works.
AUX relay: Potential-free contact (normally open
contact). Contact is connected with K2 (number 23)
if coil is connected to power.
Equipped with a detachable bridge to A+ (number
25) ex works.
AUX relay: Coil's minus connection. AUX relay activ-
ates if coil is connected to power.
GND. Connection for power supply.
For information on connecting to a SmartRelay, refer
to the system manual of the corresponding
SmartRelay.
MOD.SOM8