Télécharger Imprimer la page

Sunjoy A302008620 Instructions D'installation page 8

Publicité

Les langues disponibles

Les langues disponibles

PLEASE READ THE FOLLOWING SAFETY RULES
WARNING:
The appliance is not for use with solid fuels.
The installation must conform with local codes or,
in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223. 1/NFPA 54, NFPA58
Natural Gas and Propane Installation Code,
CSA B149.1, or Propane Storage and Handling
CODE,B149.2.
Theappliance, when installed,mustbe electrically
grounded in accordance with
local codes or,in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
Before use,check for damaged parts such as
hoses, regulators, pilot, or burner.
Inspect the fuel supply connection for signs of
leakage (including the hose for LP models) before
each use of the appliance.
All leak tests should be done with a soapy
solution. NEVER USE AN OPEN FLAME TO CHECK
FOR LEAKAGE.
Children and adults should be alerted to
the hazards of high surface temperatures and
should stay away to avoid burns or clothing
ignition.
Young children should be carefully supervised
when they are in the area of the appliance.
Clothing or other flammable materials should not
be hung from the appliance,or placed on or
near the appliance.
Any guard or other protective device removed
for servicing the appliance must be replaced
prior to operating the appliance.
Installation and repair should be done by a
qualified service person. The appliance should
be inspected before use and at least annually
by a qualified service person.
More frequent cleaning may be required as
necessary. It is imperative that control
compartment,burners, and circulating air
passageways of the appliance be kept clean.
Keep the appliance area clear and free from
combustible materials,gasoline and other
flammable vapors and liquids.
DO NOT OBSTRUCT the flow of combustion
and ventilation air.
Keep the ventilation opening(s) of the cylinder
enclosure free and clear from debris.
The appliance shall be used only in a well-
ventilated space and shall not be used in a
building, garage or any other enclosed area.
An appliance may be installed with shelter no
more inclusive than: With walls on all
sides,but with no overhead cover.
Within a partial enclosure which includes an
overhead cover and no more than two side
walls,these side walls may be parallel, as in a
breezeway,or at right angles to each other
8

Publicité

loading