is in operation.
Before operating your new pump, have
a specialist check:
-
The earthing, the protective multiple
earthing; the residual current circuit
breaking must be compliant with
the safety regulations of the energy
supply company and function with-
out fault,
-
The protection of the electrical plug
connections from the wet.
If there is a risk of flooding, fix the
plug connections in an area that is safe
from flooding.
Ensure that the mains voltage matches
the specifications on the rating plate.
The electrical installation shall be ac-
cording to national wiring rules.
Connect the equipment only to a sock-
et with a residual current protection
device (residual current circuit breaker)
with a rated current of not more than
30 mA; minimum fuse 6 amperes.
Before each use, check the equipment,
cable and plug for damage. Defec-
tive cables are not to be repaired, but
rather replaced by new ones. Have
damage on your equipment repaired
by an authorised specialist.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified per-
son in order to prevent hazards.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
Do not carry or fix the equipment by
the cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
Disconnect the mains plug from the
socket before all work on the equip-
ment, in case of leaks in the water sys-
tem, during work breaks, and when not
in use.
The cross-section of mains connection
lines must be no smaller than rub-
ber hose lines with the designation
H07RN8-F. The line must be 10 m long.
The flexible lead cross-section of the
extension cord must at least 2.5 mm
Start-up
Assembly
To screw-on the adapter:
1. Screw the angle adapter (11)
and the adapter with the hose
connection (9) onto the pump
outlet (5).
Installing the float switch
2. Position the float switch cable (7)
in the float switch grid (8).
Connection of the pressure
line
The installation of the submersible water
pump is implemented either
-
with fixed pipe or
-
with flexible hose line
• If using a ½" hose, attach the
hose over the pump's hose con-
nection (9) and fasten it with a
hose clamp if necessary.
• To use a ¾", 1" or 1½" hose, cut
off the connection above and at-
tach the hose over the correct con-
nection
(fixing with a hose
• To use a tap adaptor (IG 1 ½ ")
to connect external hose connec-
GB
.
2
clamp).
35