5. Cover body (B) with lid (A). To lock in place, turn
clockwise. To unlock, turn counterclockwise.
OPERATING INSTRUCTIONS
Perform leak test in a well-ventilated area outside and where no source of spark can occur. DO NOT
cover firepit directly after flame is out. Wait 5 minutes for firepit to cool prior to placing lid on firepit.
Connect tank cylinder to regulator. Turn the on/off valve at the unit to the 'OFF' position to pressurize
the control system. Use a soapy water solution to check all the connection leaks before attempting to
light the appliance.
If a leak is found or you smell gas, disconnect cylinder and turn valve off and do
not use the appliance until repairs can be made.
Lid must be removed when burner is in operation.
Firebowl and propane gas cylinder minimum distance
must be over 60'' (as per the right side photo)
TO LIGHT
1. Control knob must be in the "OFF" position.
2. Connect propane cylinder, open cylinder valve.
3. Push in knob in fully and rotate about 1/4 turn "counter clockwise" until a click is heard.
4. If ignition does not occur, repeat step 3 in rapid succession for no more than 5 seconds or until burner ignites.
If ignition still does not occur, immediately turn the burner control off, wait 5 minutes for the gas to clear and repeat
lighting procedure.
5. After burner ignites, adjust flame to desired flame with the control knob.
7