V.3 Adjustable Delayed Auto Power-Off Activation
This feature allows a delayed power-off after the end of the cooking phase so that the right level of air purity in your
kitchen is restored as quickly as possible.
With the hood in operation, choose the desired speed, then press and hold the T2+T3 button for a few seconds until all
the LEDs start to flash (T1, T2, T3, T4). By pressing one of the buttons (T1,T2,T3,T4), the auto power-off time can be
programmed, as follows: T1 for 5 minutes; T2 for 10 minutes; T3 for 15 minutes; T4 for 20 minutes
During auto power-off operation, the set speed (including intensive speed) can be changed. If the power-off time
chosen is the same as the set speed, the speed LED flashes; if a different time is chosen, the speed LED remains steady.
The hood must be switched off to disable the self-switch-off.
If this function is to be handled via the remote control, the auto power-off is preset to 15 minutes and motor speed 1.
When the 15 minutes has elapsed, the motor switches off automatically. To activate it, press and hold button
while the hood is switched on at any speed. The timer is deactivated by switching off the motor using button
V.4 Maintenance alerts
Metal anti-grease filters
Every 30 hours of hood operation, when the hood is switched off, all speed button LEDs illuminate with a steady or
flashing light for 30 seconds to signal that the metal anti-grease filters need to be cleaned. To reset the timer, simply
press and hold button T4 with the extractor switched off. If this operation is not carried out, the device will sound an
alarm again the next time the hood is switched off.
Carry out the following to reset the timer via remote control:
Press and hold button
V.5 24-hour Comfort function
This function allows the continuous air renewal in your kitchen when the hob and the range hood are not being used.
Air extraction cycles are activated at programmed time intervals: 5 min ON – 25 min OFF. These timed cycles clean the
air of any lingering odours as cigarette smoke, detergents and stagnant and stuffy smells. This function is easy to activate
and deactivate when required or can be left on for 24 hours.
Press the TR button to select the 24-hour Comfort function, which stays active for up to 24 hours. The extractor switches
on at speed 1 for 5 minutes, then switches off automatically and repeats cyclically every 25 minutes.
During the extraction phase, the TR button flashes every second and during the 25-minute interval it flashes every 5
seconds. The function can be deactivated at any time by pressing the TR button.
To activate this function via remote control, long press and hold
hood will also be switched off.
VI MAINTENANCE AND CLEANING
Warning! Before any maintenance or cleaning operation, disconnect the hood from the power
supply by setting the main switch of the domestic system to "off".
VI.1 Metal anti-grease filter
Particular attention should be paid to the metal grease filter, which has the function of retaining the fat particles
contained in the vapors. The grease filter must be washed when the warning appears or at least once a month, use hot
water and detergent (or put it in the dishwasher). The filter may become discolored after a few washes. This is normal
and does not mean that it needs to be replaced.
To remove the metal anti-grease filter, use the handle on the filter itself (Fig. 6.1.1).
It is recommended to refit the metal grease filter only if perfectly dry.
ATTENTION: the grease collected in the filters can easily catch fire and it is therefore extremely
important to clean the metallic filters regularly as per instructions
with the extractor switched off.
. To deactivate it, press button
13
and the