IV USE
This hood has been designed to work exclusively in filtering mode.
The aspirated fumes pass through the Plasma filter and are re-introduced into the kitchen without odors (Fig. 4.1).
V OPERATION
The hood is equipped with a multi-speed motor. It is advisable to use the low speed in normal conditions and the other
speeds when high concentrations of odours or vapours are present. It is also advisable to start the hood when cooking
begins and to keep it running until the odours have disappeared.
V.1 Operating the hood controls
The controls on the hood (Fig. 5.1.1) are fitted with the following buttons:
TL: Lamp switch on/off and light temperature adjustment.
T1: Switch-on at speed 1 and extractor off.
T2-T3: Operation at speeds 2 and 3 respectively.
T4: Intensive speed setting (maximum extraction), the extractor operates at this speed for 5 minutes (with button
flashing) and then automatically switches speed 3.
TR: 24-hour Comfort function
PL: Plasma filter operation LED indicator light
Light adjustment:
TL single click: on/off at the stored brightness and temperature.
TL double click when off: minimum brightness (10% brightness, ambient light).
TL long press (for more than 1 second) when on: brightness adjustment:
• Starting from stored setting, DOWN → UP adjustment, when not released, the maximum brightness is set.
• With an additional long press, the UP → DOWN adjustment is carried out to the minimum brightness.
• When the button is released, both at maximum/minimum or during adjustment, the desired intensity is stored for
the next switch-on.
TL+TR with light on: colour temperature adjustment (same procedure as intensity adjustment).
V.2 Remote control operation
Remote control encoding
The included remote control is already encoded and ready to fully control the hood.
In the event that the remote control is replaced, a new encoding is required.
After switching on the power supply, all LEDs on the hood will light up alternately (Fig. 5.1.1). Within 10 seconds, press
and hold any button on the remote control until an acoustic signal is heard that indicates successful completion of the
procedure.
When the LEDs go out, programming is complete and it will no longer be possible to program the remote control.
Remote Control Operation
For the remote control buttons, refer to Fig. 5.2.1.
Extraction switch on/off.
The motor always runs at speed 2.
A long press activates the 24-hour comfort function, which can be cancelled by pressing button
switched off.
Lighting switch-on.
Successive single presses allow switching between maximum and minimum brightness;
Long presses (with the light on) change the intensity.
Spegnimento illuminazione.
Se premuto a lungo (con luce accesa) si modifica la temperatura.
With the motor running, an increase in speed up to speed 4.
A long press (with the motor switched off) resets the anti-grease filter timer; an acoustic signal of approx. 1 second is
sounded as confirmation.
With the motor running, a reduction in speed to speed 1.
A long press (with the motor running), activates the auto power-off timer (the motor switches to speed 1 and switches
off after 15 minutes). The timer is deactivated by switching off the motor using button
12 
 
and the hood is also
.