the user loses control of the hammer. When a jam
is detected, the torque and speed are reduced
instantly. This feature prevents self rotation of the tool
reducing the occurrence of wrist injuries.
Service Indicator LEDs (fi g. 3)
The yellow brushwear indicator LED (s) lights up
when the carbon brushes are nearly worn out to
indicate that the tool needs servicing within the next
8 hours of use.
D25721, D25722, D25723, D25761, D25762, D25763
The red service indicator LED (r) lights up if the
lock-on button (b) is used in any mode except the
chipping mode. On models fitted with Ultimate
Torque Control (UTC), the red LED indicator (r) lights
up if the anti-rotational device is activated. The red
indicator starts to flash if there is a fault with the tool
or the brushes have completely worn out (refer to
Brushes under Maintenance).
D25871
The red service indicator LED (r) lights up if there is
a fault with the tool or the brushes have completely
worn out (refer to Brushes under Maintenance).
Fully Vibration-dampened Main
Handle (fi g. 1)
The dampers in the main handle (d) absorb the
vibrations transmitted to the user. This improves user
comfort during the operation.
Electrical Safety
The electric motor has been designed for one
voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your D
WALT tool is double insulated in
E
accordance with EN 60745; therefore no
earth wire is required.
WARNING: 115 V units have to
be operated via a fail-safe isolating
transformer with an earth screen
between the primary and secondary
winding.
If the supply cord is damaged, it must be replaced
by a specially prepared cord available through the
D
WALT service organisation.
E
Mains Plug Replacement
(U.K. & Ireland Only)
If a new mains plug needs to be fitted:
• Safely dispose of the old plug.
• Connect the brown lead to the live terminal in
the plug.
• Connect the blue lead to the neutral terminal.
WARNING: No connection is to be
made to the earth terminal.
Follow the fitting instructions supplied with good
quality plugs. Recommended fuse: 13 A.
Using an Extension Cable
If an extension cable is required, use an approved 3–
core extension cable suitable for the power input of
this tool (see technical data).The minimum conductor
2
size is 1.5 mm
; the maximum length is 30 m.
When using a cable reel, always unwind the cable
completely.
ASSEMBLY AND ADJUSTMENTS
WARNING: To reduce the risk of
injury, turn unit off and disconnect
machine from power source before
installing and removing accessories,
before adjusting or changing set-
ups or when making repairs. Be sure
the trigger switch is in the OFF position.
An accidental start-up can cause injury.
WARNING: Tool bits may be hot and
gloves should be worn when changing
or removing them to avoid personal
injury.
Assembling and Fitting the Side
Handle (fi g. 2A, 2B)
The side handle (c) can be mounted on either side
of the machine to suit both right- and left-handed
users.
WARNING: Always operate the
tool with the side handle properly
assembled.
D25721, D25722, D25723, D25761, D25762, D25763
MOUNTING IN FRONT POSITION (FIG. 2A)
1. Snap the steel ring (j) over the collar (n) behind
the tool holder (l). Squeeze both ends together,
mount the bush (k) and insert the pin (m).
2. Place the side handle clamp (i) and screw on
the clamp wheel (h). Do not tighten.
WARNING: Once assembled, the side
handle clamp should never be removed.
3. Screw the side handle (c) into the bush (k) and
then into clamp wheel. Tighten securely.
EN G LI SH