Télécharger Imprimer la page

MEIER-BRAKENBERG MBH1500K Manuel D'utilisation page 17

Nettoyeur à haute pression - eau froide

Publicité

Les langues disponibles

Les langues disponibles

7. Maintenance
7.1 Before each use
-
Check the power supply cable. The cable must not be damaged (risk of electric shock). An authorised
electrician must replace the damaged power lead immediately.
-
Check high-pressure hose for damages (risk of bursting); if damaged replace immediately.
Measures at risk of frost:
7.2 Service notes on high-pressure pump (drawing)
-
Tighten screw (pos. 1 in drawing HE006W/HE007W, appendix) with 50 Nm (5.1 kgm)
-
Tighten valve cover (pos. 3 in drawing HE006W/HE007W, appendix) with 68 Nm (6.9 kgm)
-
Tighten nut bolt (pos. 17 in drawing HE006W/HE007W, appendix) with 12 Nm (1.2 kgm)
-
Tighten rod bolt with 10.4 Nm (1.1 kgm)
-
Tighten bearing screw (pos. 28 in drawing HE006W/HE007W, appendix) with 24.5 Nm (2.5 kgm)
7.3 Oil level high-pressure pump (check regularly)
-
Check the oil level in the crankcase before starting operation of the cleaner.
-
Check with oil dipstick.
-
Check in fresh oil tank approx. 2 cm.
-
First oil change after approx. 50 hours of operation, subsequently every 300 operating hours or every
6 months.
Oil change:
- Open oil-drain screw.
- Let oil drain off into collecting tray.
- Close oil-drain screw.
- Fill in new oil slowly, oil must reach the middle of the oil level indicator.
Applicable oil: SAE 10W-60 fully synthetic (Item.-No.: WB0011-01)
7.4 Filter
The standard water filter is on the backside of the device at the water inlet connection behind the Geka-
coupling towards the high-pressure pump.
Check the filter regularly (at least 1 x daily) and clean if applicable. Screw off the filter casing and rinse
filter.
Contaminated filters lead to water shortages and therefore damages the pump.
8. Standard accessories
8.1 High-grade steel cover
Take off cover for maintenance work:
-
Extra equipment „hose coiler": Disconnect connection hose from device to hose coiler at the
swivel joint.
-
Unfasten 4 fixing screws mit PVC head on the right and left side of the device chassis (do
not unscrew completely).
-
Remove cover frontwards.
Store the device safe from frost!
page 7 of 10