When operating in suction process from a feed tank use a 1 1/2 " suction hose of max. 5 m with
suction coupling.
-
Devices with control (start/stop automatic): backfitting is required for suction process!
Cleaners with backfitting kit (see point 4.6): When operating in suction process from a feed tank use
a 1 1/2 " suction hose of max. 5 m with suction coupling.
-
The water pressure of the feed line must be between +2 bar and +10 bar.
-
Observe the regulations of the water supply company.
d
-
There is a filter screen between the Geka-coupling and the high-pressure pump. Check the screen
regularly and clean the screen if applicable.
d
-
Connect with a pressure and suction resistant water hose with fabric lining to water supply.
-
Connect to the water connection of the device and the building's water tap.
-
Attention: If there is mounted an non-return valve in the water-supply line, it has to be installed an
expansion tank between non-return valve and presusre cleaner! Otherwise componentens of the
pressure cleaner can be damaged!
4.5 Starting the cleaner
-
Couple hoses and electrical connection.
-
Open water tap!
-
Activate high-pressure torch and wait until water pours out without air entrapment, close torch.
d
-
Turn on operating switch.
d
Start the device with the operating switch on "star" position and switch over to "triangle" after a
-
short start-up period.
CAUTION: Operate the motor only in "triangle" position when using cleaning mode.
-
The device is now ready for operation.
-
Pressure must build up immediately!
-
In case of no pressure build-up check:
jet „clean"
feed line filter blocked (unsufficient water supply)
-
The rotational direction of the high-pressure pump is irrelevant!
4.6 Function start/stop automatic
Only for start/stop type:
-
The motor starts
(„EIN")
-
The device switches off („AUS") after the preset overtravel time of approx. 30 sec.
(torch not being used for more than approx. 30 sec.)
Operational availibility:
-
Switch the device to
green light between the green I-button and the red 0-button shows readiness for operation.
-
The high-pressure cleaner works when the pump is activated. The pump continues to work
for approx. 20 to 30 sec and stops automatically after releasing the torch.
-
Turn off operational availibility by pressing the red 0-button. The green LED goes off.
when opening the high-pressure torch.
„Betriebsbereit"
page 5 of 10
(ready for operation) by pressing the green I-button. A