Power on.
Check LCD diplay shows short level and et Leq picked up by the sensor as the date and hour.
Open
the upper plexiglas hood.
Enter the code.
Analysis/Regulation filter configuration setting.
The settings are available in front panel of the equipment (screwdriver)
The historical filter must be configurated in "Weighted A"
The control filter can be fixed in Weighted A for a classical or intermediary M regulation if we take account a little bit more
bottom of audio spectral.
This solution can enable a better operating in case of a important lower frenquencies and avoid the flutter by medium
frequencies when they exist.
Activate sensor mode or line mode via the commutator 6 (Régulation)
Remarque : Intermediary M, the control is more strict; values picked up will be lower at authorized values.
Time setting.
Select the
to time settings
1
using of numerical
Idem for all parameters.
AMIX
FUNCTIONING MODE: MODE 2
SNA 50-2 line mode
Enter the code
1
using of numerical
keyboard
(1052 by default)
PAGE
3
page
Validate
minutes
Enter minutes
keyboard
minute value
not valid
the code
0
5
2
code value
Select the parameter
to modify
another parameter
ENTER
ESCAPE
29
Validate
ENTER
ESCAPE
not valid
1
Minute settings (0 to 59)
2
Hour settings (0 to 23)
1 3
Day settings (0 to 31)
5
Month settings (1 to 12)
6
Year settings (00 to 99)
Modify
ESCAPE
of the page 3
ESCAPE
Leave page 3
ESCAPE
SNA 50-2