Power on.
Check LCD diplay shows short level and et Leq picked up by the sensor as the date and hour.
Open
the upper plexiglas hood.
Enter the code.
Analysis/Control filter configuration setting.
The settings are available in front panel of the equipment (screwdriver)
- The historical filter must be configurated in "Weighted A"
- The control filter can be fixed in Weighted A for a classical or intermediary M regulation if we take account a little bit more
bottom of audio spectral.
This solution can enable a better operating in case of a important lower frenquencies and avoid the flutter by medium
frequencies when they exist.
- Activate sensor mode or line mode via the commutator 6 (Régulation)
Remark : Intermediary M, the control is more strict; values picked up will be lower at authorized values.
Time setting.
Select the
page
to time settings
1
using of numerical
Idem for all parameters.
AMIX
FUNCTIONING MODE : MODE 1
MODE 1 : SNA 50-2 sensor mode
Enter code
1
using of
numerical keybord
(1052 by default)
PAGE
3
Validate
minutes
Enter minutes
keyboard
minute value
not valid
Validate
the code
0
5
2
code value
not valid
Select the parameter
to modify
another parameter
ENTER
Leave page 3
ESCAPE
22
ENTER
ESCAPE
1
Minute settings (0 to 59)
2
Hour settings (0 to 23)
1 3
Day settings (0 to 31)
5
Month settings (1 to 12)
6
Year settings (00 to 99)
Modify
ESCAPE
of the page 3
ESCAPE
ESCAPE
SNA 50-2