UNPACKING THE DEHUMIDIFIER
Use the cut line on the carton to pulll carton off dehumidfier�
INCLUDED IN THE CARTON
• Dehumidifier
• Installation manual
• Hanging brackets
• Model S77 control
• 3/4" P-Trap
• 3/4" MNPT x 3/4" hose barb fitting
LOCATION CONSIDERATIONS
This appliance is classified as to not be accessible to the general public�
The dehumidifiers should be spaced evenly throughout the area to be
dehumidified with the following recommendations:
1. Avoid placement where the discharge of one dehumidifier is
pointing toward the inlet of another�
2. Avoid locating the dehumidifier inlet too near a supply register�
Space is not usually available to totally avoid this, but minimizing
the amount of cold air that is discharged to the dehumidifier inlet
will improve moisture removal performance of the dehumidifier�
3. Account for handling dehumidifier condensate by considering drain
or sump pump locations�
4. Leave appropriate room on the drain side of the dehumidifier for
wiring and service�
5. Allow sufficient space near the inlet (6" minimum) to be able to
remove/install a filter� More space ensures no loss of airflow due to
restriction at the inlet�
4 English
• 3/4" MNPT x 3/4" female pipe
• 3/4" FNPT x 3/4" female pipe
• 10 feet of 3/4" clear PVC flexible drain hose
• Terminal screwdriver
• 30 feet of thermostat cable
• MERV 11 filter
FIGURE 2 – SPACE CLEARANCES
6"
MIN.
INLET SIDE
ELECTRICAL
SERVICE PANEL