Configuration B - Ventilation and CANALIZATION:
Warm air output from the front and rear side of the appliance: REMOVE the semi-blanks
a)
b)
Perform the drilling on the walls to allow the passage and the application of the (fire-resistant) hoses equipped with related
openings.
c)
Fasten the pipes by means of clamps to the related collars and openings.
d)
Each pipe must not exceed 4 m for forced ventilation, and has to be insulated with insulating materials to avoid noise and loss
of heat.
e)
The openings have to be positioned at a height not lower than 2 m from the floor to avoid that hot air at output meets people;
Please respect the distance of the convection openings according to the local construction norms.
f)
The lengths of the canalization pipes must have the same length to avoid the distribution of differing quantities of air from each
Picture 6
output. (see

ELECTRICAL CONNECTION

The installation and the connection of the product has to be carried out by authorized personnel according to the current
regulations (see chapter GENERAL PRECAUTIONS). La NORDICA S.p.A. declines any responsibility for the product that has
been modified without written authorisation as well as for the use of non-original spare parts.
ATTENTION: do NOT place the electric cable nearby hot parts.
CONNECTION: Connect the electric cable to a bipolar switch with a distance of at least 3 mm between the contacts (Power source
230 V~ 50 Hz, the correct connection to the grounding system is necessary).
WARNING: This operation must be carried out without power supply !!
WARNING: The PRODUCT must be connected to the mains with a differential line cut-off switch according to the regulations
in force. Improper use relieves the manufacturer from each responsibility.

ALLOWED / NOT ALLOWED FUELS

Allowed fuels are logs. Use exclusively dry logs (max. content of water 20%). Maximum 3 logs should be loaded. The pieces of wood
should have a length of ca. 20-30 cm and a maximum circumference of 30-35 cm.
Compressed not worked-out wood briquettes must be used carefully to avoid overheating that may damage the device,
since these have a very high calorific value.
The wood used as fuel must have a humidity content lower than the 20% and must be stored in a dry place. Humid wood tends to burn
less easily, since it is necessary a greater quantity of energy to let the existing water evaporate. Moreover, humid content involves
the disadvantage that, when temperature decreases, the water condensates earlier in the hearth and therefore in the stack causing
a remarkable deposit of soot with following possible risk of fire of the same.
Fresh wood contains about 60% of H
It is necessary to place this wood in a dry and ventilated place (for example under a roofing) for at least two years before using it.
Besides others, it is not possible to burn: carbon, cuttings, waste of bark and panels, humid wood or wood treated with
paints, plastic materials; in this case, the warranty on the device becomes void.
Paper and cardboard must be used only to light the fire.
The combustion of waste is FORBIDDEN and would even damage the appliance and the flue, causing health damages and claims
by the neighborhood owing to the bad smell.
The wood is not a fuel which allows a continuous operation of the appliance, as consequence the heating all over the night is not
possible.
Variety
Beech
Oak
Elm
Poplar
Larch*
Spruce*
Scots pine *
ATTENTION : the continuous and protracted use of aromatic wood (eucalyptus, myrtle etc.) quickly damages the
cast iron parts (cleavage) of the product.
The declared technical data have been achieved by burning beech wood class "A1" according to the requirement UNI EN ISO 17225-
5 and wood moisture content less than 20%. By burning a different kind of wood the efficiency of the product itself could change and
some specific adjustments on the appliance could be needed.
- B)
O, therefore it is not suitable to be burnt.
2
*
RESINOUS WOOD NOT SUITABLE FOR THE BURNING
kg/mc
750
900
640
470
660
450
550
ENgLIsH
(Picture 6
- B)
kWh/kg
20%
moistness
4,0
4,2
4,1
4,1
4,4
4,5
4,4