FO 6500
TECHNICAL MANUAL. TECHNICAL INSTRUCTIONS FOR INSTALLATION.
WARNING
- This appliance must be installed in accordance with current regulations.
- Please read instructions before installing and using this appliance.
- Only use outdoors.
- Do not move the appliance when in use.
- Close the gas supply to the bottle after use.
- Any modification of the appliance may be dangerous.
- This appliance must be kept away from flammable materials.
All the actions indicated in this manual must be carried out by qualified persons and in accordance
with applicable regulations.
This appliance can work with liquid gas with no need for regulations.
TECHNICAL DATA:
-
Category I 3+
-
Type of gas G30/G31
-
Regulator. Supply pressure 28-30/37 mbar
This utensil is class 1: free-standing cooking appliance.
WARNING: Make sure that the appliance is regulated for the type of gas supply.
BURNER NOMINAL CONSUMPTION
INJECTOR
BURNER
(mm)
Big
buner,
0,80
left
Big
burner,
0,80
right
Central
0,69
burner
Total
Bottle capacity can not exceed 12.5 kg.
The rating plate with the characteristics found in the rear of the unit.
Power kW
norm. kW red. kW
3,15
228,9
3,15
228,9
2,70
196.2
9
654
ENGLISH