Trouble
1. Fan does not operate when dryer begins cycle.
2. Fan is operating, but air moves slower than normal.
3. Fan is operating louder than normal.
All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or
material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years
from the date of purchase against defects in workmanship and/or material.
This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as: range
hood grease filters, charcoal filters or combination charcoal/grease filters; replacement light bulbs in range hoods or bathroom fan/light/bulb
heater combinations. As well, any damage or failure caused by abuse, misuse, abnormal usage, faulty installation, or improper maintenance
will not be covered by this warranty.
In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original
bill of sale showing: date of purchase, place of purchase and model purchased. Failure to meet these requirements will void your warranty.
Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly
by the product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do
not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you
specific legal rights and you may have other rights which vary from state to state and province to province.
Please call: 1-800-465-7300, MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.
Reference the type and style of product (located on label inside of the product) when you call.
#
Qty. Description
1
1
Motor
2
1
Cover Plate
3
2
Screw
4
1
Mounting Bracket
5
3
Grommet
6
3
Screw
7
1
Pressure Sensor Switch
8
8
Screw
9
1
Identifying Label
Installer: _________________________________________________________ Installation Date:_________________________________________
Place of Purchase: _________________________________________________ Model Number: __________________________________________
AIDB4YEF New 3-07
Troubleshooting Guide
Probable Cause
1a. A fuse may be blown or a circuit tripped.
1b. Wiring is not connected properly.
1c. Pressure switch mounted incorrectly
1c. Motor has stopped operating.
2a. Obstruction in the exhaust ducting.
3a. Lint buildup in motor.
3b. Motor is loose.
3c. Fan mounting screws too tight.
3d. Fan damaged in shipping.
LIMITED WARRANTY
FOR PARTS OR TECHNICAL ASSISTANCE
PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.
For more information please visit our website: wwwairkinglimited.com
Replacement Part #
5S7635000
5S7635029
5S7699021
5S7635035
5S7699020
5S7699024
5S7635046
5S7699022
5S7635047
www.airkinglimited.com
Suggested Remedy
1a. Replace fuse or reset circuit breaker.
1b. Turn off power to unit. Check that all wires are connected.
1c. Turn off power to unit. Reposition switch in correct position.
1c. Replace motor.
2a. Check for any obstructions in the ducting. The most common are bird nests
in the roof cap or wall cap where the fan exhausts to the outside.
3a. Follow instructions in USE and CARE section of these instructions.
3b. Turn off power to unit. Confirm unit is mounted securely to bracket.
Restore power to unit.
3c. Turn off power to the unit. Loosen screws going through rubber grommets
3d. Contact seller for replacement.
3
2
5
4
6
1
8
9
This dryer exhaust is equipped with an
Air King automatic dryer booster fan.
Verify proper operation each month:
Turn the dryer on for one minute than turn it
off. Verify that air keeps flowing through the
dryer filter opening after the dryer is off.
Air King
website: www.airkinglimited.com • phone 877-304-3785
Install on wall by dryer - DO NOT REMOVE
7
4 of 8