14
TROUBLE SHOOTING
Disconnect the machine from the power supply prior to any checks performed at the machine
itself!
Trouble
Pressure can no
longer be stored
Engine overheats
Compressor runs
but produces no
pressure
Engine will not start
After reaching the
escapes cut-off
pressure
Compressed air
through the relief
valve und Pressure
switch to reach the
starting pressure
Compressor on
frequently
MANY POTENTIAL SOURCES OF ERROR CAN BE CLEARED BY THE EXPERTLY CONNECTION
TO THE ELECTRICITY GRID.
Should you in necessary repairs not able to properly to perform or you have
not the prescribed training for it always attract a workshop to fix the problem.
ZIPPER MASCHINEN GmbH
www.Zipper-Maschinen.at
ZI-COM150-10 ; ZI-COM200-10
Possible cause
Valve seals broken
low oil level
dirty air filter
Clogged air filters
Defective seals
Defective valves in the cylinder
head.
No power supply
Overload protection activated
Leaking or defective check valve
Check valve is damaged
Very much condensate in the
pressure boiler
Overload compressor
Replace the seals
Refill oil
Clean or replace the air filter
Clean or replace the old air filter
Replace the seals
Replace the valves
Check the connection to an existing
electrical grid.
Let the engine cool down and then
pull the red pressure switch (on /
off)
Clean or replace check valve insert
Replace check valve
Drain condensate
NOTICE
TROUBLE SHOOTING
Solution
23