PROBLEM
Work-contacting element does not de-
press fully - tool does not operate
Tool operates properly, but fasteners do
not drive fully
Tool operates properly, but fasteners are
driven too deep
Tool jams frequently
Tool stops and LED flashes rapidly
Tool has charged battery and LED is
slowly flashing or LED does not turn
off after approximately ten seconds of
non-use
Tool will not drive a fastener or cycles
without driving a fastener
AFTER FRENCH AND SPANISH LANGUAGE SECTIONS.
TROUBLESHOOTING
POSSIBLE CAUSE
Low nails
Work-contacting element is jammed
Air pressure is too low
Depth of drive isn't deep enough
Nail is too long for wood hardness
Trigger released too soon.
Air pressure is too high
Depth of drive is too deep
Incorrect nails
Damaged nails
Loose magazine
Dirty magazine
Battery is low or has no charge
Tool is hot
Tool has malfunctioned
Driving mechanism is dirty
NOTE: ILLUSTRATIONS START ON PAGE 12
11 — English
SOLUTION
Replenish nails
Remove battery and clear debris
Increase air pressure
Adjust depth of drive
Use nail length that is appropriate for
wood
Hold trigger until fastener is driven.
Decrease air pressure
Adjust depth of drive
Verify that nails are the correct size
Replace nails
Tighten screws
Clean magazine
Recharge battery
Allow tool to cool
Take tool to nearest authorized repair
center
Clean the nail channel as described in
the Maintenance section of the manual