Télécharger Imprimer la page

Viking Range VMOD241 Guide D'installation page 5

Masquer les pouces Voir aussi pour VMOD241:

Publicité

Les langues disponibles

Les langues disponibles

• If the DrawerMicro Oven is ever moved to a
different location, the Anti-Tip block must also be
moved and installed. When installed to the wall,
make sure that the screws completely penetrate
the dry wall and are secured in wood or metal so
that the block is totally stable. When fastening, be
sure that the screws do not penetrate electrical
wiring or plumbing.
3
5"
(127 mm)
Electrical Outlet
• The electrical requirements are a 120 volt 60 Hz,
AC only, 15 amp. or more protected electrical
supply. It is recommended that a separate circuit
serving only this appliance be provided.
• The appliance is equipped with a 3-prong
grounding plug. It must be plugged into a
wall receptacle that is properly installed and
grounded. Should you only have a 2-prong
outlet, have a qualified electrician install a
correct wall receptacle.
Note:
If you have any questions about the grounding
or electrical instructions, consult a qualified
electrician or service person.
6"
(153 mm)
Anti-tip
Block
Drawer Installation
4
Electrical Outlet
Location
5
A
PARTS SUPPLIED
4 Screws
DRAWER INSTALLATION: Place the DrawerMicro Oven
adjacent to the wall or cabinet opening. Plug the power supply
cord into the electrical outlet Carefully guide the appliance
into the prepared opening. Avoid pinching the cord between
the oven and the wall. Slide the drawer all the way until the
mounting flange is flush with the face of the cabinet. Open the
drawer. Using the 4 holes on the drawer as a template, pre drill
the cabinet using a 1/16" bit. See figure 5A. Secure the drawer
with the 4 screws supplied. See figure 5B.
E5
5"
(127 mm)
4"
(101.6 mm)
Mounting
Flange
B

Publicité

loading

Ce manuel est également adapté pour:

DrawermicroCvmod241