▶ Operation is permissible only when connected to a power source providing a voltage and frequency in
compliance with the information given on the type identification plate.
3.3
Items supplied
Breaker, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4
Technical data
4.1
Breaker
For rated voltage, rated current, frequency and/or input power, refer to the country-specific type
identification plate.
If the device is powered by a generator or transformer, the generator or transformer's power output must be
at least twice the rated input power shown on the rating plate of the device. The operating voltage of the
transformer or generator must always be within +5 % and -15 % of the rated voltage of the device.
This device complies with the applicable standard provided that the maximum permissible supply impedance
(Zmax) at the point where the user's installation is connected to the public supply network is less than or
equal to 0,401 Ω. It is the responsibility of the installer or user of the device to ensure, if necessary by
consultation with the supply network operator, that the device is connected only at a point where supply
impedance is less than or equal to Zmax.
Weight
Protection class in accordance with EN 60745
5
Operation
5.1
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.2
Connecting the detachable supply cord
CAUTION
Risk of injury! Due to leakage current as a result of dirty contacts.
▶ Connect the detachable electric connector to the electric tool only when it is clean and dry and when the
supply cord is unplugged from the power outlet.
1. Push the keyed, detachable electric plug connector into the tool as far as it will go, until it is heard to
engage.
2. Plug the supply cord into the power outlet.
5.3
Disconnecting the detachable supply cord
1. Unplug the supply cord from the power outlet.
2. Press the release button and pull the keyed, detachable electric plug connector out of the socket.
3. Pull the supply cord connector out of the power tool.
*2227845*
2227845
TE 500
4.9 kg
(10.8 lb)
II
English
5