The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the side
burner and should be in a location that allows ease of opening
and closing. Do not block access to the shutoff valve. The valve
is for turning on or shutting off gas to the side burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To side burner
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected side burner location in accordance with
the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest
edition, and local codes. For conversion to Natural gas, the
Natural gas conversion kit supplied with the side burner must be
used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit
supplied with the side burner must be used. Follow instructions
for converting to Natural gas in the "Gas Conversions" section.
A. New CSA International approved
"outdoor" flexible gas supply line
B. Rear of side burner
C. To Natural gas supply
The gas supply line shall be equipped with an approved shutoff
valve. This valve should be located in the same area as the side
burner and should be in a location that allows ease of opening
and closing. Do not block access to the shutoff valve. The valve
is for turning on or shutting off gas to the side burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To side burner
12
B
C
A
B
C
B
C
Gas Connection Requirements
For Models Equipped for Natural Gas
Natural Gas
Built-in side burner models are equipped for use with Natural
gas. They are design-certified by CSA International for LP
(propane or butane) gases with appropriate conversion.
Built-in models are set for Natural gas use and have a pressure
regulator with ½" female pipe threads.
A
A. Side burner gas pipe
B. New CSA International approved
"outdoor" flexible gas supply line
C. Rear of side burner
D. To Natural gas supply
The supply line shall be equipped with an approved shutoff valve.
This valve should be located in the same area as the side burner
and should be in a location that allows ease of opening and
closing. Do not block access to the shutoff valve. The valve is for
turning on or shutting off gas to the side burner.
A
A. Gas supply line
B. Shutoff valve "open" position
C. To side burner
LP Gas Conversion Using a Local LP Gas Supply
Conversion must be made by a qualified person. A qualified
Natural gas technician shall provide the LP gas supply to the
selected side burner location in accordance with the National
Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local
codes.
B
C
D
B
C