Then, it is necessary to prepare the wrench's calibration data and the tester. This process consists
of 3 points:
1. Calculate the wrench's 20%, 60% and 100% maximum torsion range and
2. Do a testing to obtain the tester's values.
3. In the testing with a determined weight, get the wrench's value and write it down. Please see
the next image as example:
Example of test data:
% OF MAXIMUM
TORQUE
20%
60%
100%
20%, 60% and 100% of the maximum torque range are calculated for the torque wrench and the
test is carried out to obtain the values of the tester.
It is necessary to connect the dynamometric wrench in off mode to the computer. Then,
turn it on and set it in SEND mode.
- Press U/S for some seconds (till hearing a sound).
- Press U/S
- Press U/S
- Press C
- Press U/S
- Press ^
Please, select the communication port number (it usually is the no. 1, but it can differ in laptops
TORQUE WRENCH
48.6
91.8
135
TESTER
48
91
135
81