Télécharger Imprimer la page

EGAmaster 56095 Instructions page 20

Publicité

Les langues disponibles

Les langues disponibles

Model N
.
o
56095
56096
56097
56098
Operating Temperature
Environmental test *6
Electromagnetic compatibility test *7
NOTE: Accuracy is guaranteed from 20% to 100% full scale.
Note:
*1: The accuracy of the readout is guaranteed from 20% to 100% of maximum range + /- 1
increment. Calibration point is at the middle line of black circle area on the rubber handle. For
maintaining accuracy, calibrate the wrench at regular intervals (1 year recommended).
*2: Use a special designed cable (accessory) to upload record data to PC.
*3: M1 mode (for a normal bolt retightening checking).
M2 peak-hold mode (for the bolts its length is unusual longer or needs an extension bar).
*4: For torque calibration, please set at M2 track mode.
*5: Horizontal and vertical test.
*6: Environmental test:
20
Max. Torque
(N-m)
30
135
200
340
Data memory size
PC Connectivity *2
Operation Mode *3
Torque display
(M2 mode) *4
Bright LED
Unit Selection
Head Type
Gear Teeth
Battery
Storage Temperature
Humidity
Drop Test
Vibration Test *5
SPECIFICATIONS
Square Drive
(inches)
1/4
3/8
1/2
1/2
All Models
Torque
Measuring
Length (mm)
Range (N-m)
1.5~30
6.8~135
10~200
17~340
CW: ± 1%
CCW: ± 2%
250
Yes
M1 - QC mode
M2 - torque mode
Peak hold / Track
12LEDs
(2 Red + 10 Green)
N-m, ft-lb, in-lb, kg-cm
Lever Type Ratchet
36
AA x 2
-10ºC~60ºC
-20ºC~70ºC
Up to 90% non-condensing
1 m
10G
Pass
Pass
390
415
530
650