purpose. At each re-assembly of the mask, after cleaning and before use after a period of long inactivity, the mask efficiency must
be checked; to perform these checks, ARAC or ARAC Mini devices (produced by SPASCIANI) can be used.
For all information regarding maintenance courses, spare parts and control equipment, contact the Spasciani sales office.
Hooking arms and supports
The hooking arms can easily be removed and replaced (ref. Picture 1):
5.
Certification and marking
5.1 CE Certification
The full face mask have the
Regulation 2016/425/EU on PPE (Personal Protective Equipment) and to technical standards EN 136:1998 and DIN 58610, followed
by the number of the Notified Body responsible for the EC type-examination and which carries out the quality control and assurance
for the production System for ensuring EC quality of production by means of monitoring (N° 0426 Italcert S.r.l., V.le Sarca, 336,
20126 Milano - Italia).
5.2 Declaration of conformity
The EU declaration of conformity is available on the website www.spasciani.com in the Download section of the product of interest.
5.3 Marking
The CE marking, positioned on the facepiece seal, is made up of the following elements:
- Designation for the TR 82 PS (characteristic of all masks of TR 82 E family group)
-
0426: marking indicating the conformity to the basic health and safety requirements, among others to All. II of Regulation
2016/425/EU, particularly for the prerequisites related to ergonomics, safety and comfort. The number 0426 indicates the Notified
Body Italcert S.r.l, Viale Sarca 336, 20126 Milan, Italy, which is the organisation responsible for controlling the production according
Module D of Regulation 2016/425/EU.
- EN 136:98 CL3: reference standard and mask class
- Manufacturer:
- the connection system (hook) is marked on the element made of rubber with the standard DIN 58610.
- the helmet-mask combination does not have a specific marking, but the TR 82 E masks are specific to be only used with helmets
and this element is considered sufficient to indicate the intended use of the mask.
- The following parts are also marked, as required by EN 136:1998:
Component
Exhalation membrane
Connector
Facepiece seal
1.
the hooking arm (f) and replace it. Should it be necessary to replace or
inspect the OR of the arms support:
2.
3.
the hooking arm holder (c) and take all the arm support apart
4.
Fig. 1
marking which indicates its conformity to the basic health and safety requirements established in
Mark
RS401
RS4011
RS 61443
A CL3+
B CL3+
TR 82 PS
Unscrew with a hexagonal key the screw (a) that keeps in position
Take the hooking arm apart
Unscrew with a hexagonal key the screw (b) that keeps in position
Check and replace the OR (h) and (g) if necessary.
Note
for TR 82 E
for TR 82 A E CL3+ and TR 82 B E CL3+
for TR 82 E
for TR 82 A E CL3+
for TR 82 B E CL3+
Black EPDM