CP 0014
1.
Push the tool retainer upwards in the direction
of the arrow.
2.
Pull the insertion tool out.
3.
Push back the tool retainer.
9800 0547 90 | Original instructions
All manuals and user guides at all-guides.com
www.CrowderSupply.com • Toll Free: 888-883-5144
Safety and operating instructions
Operation
Preparations before starting
Check the equipment
Check that all of the equipment is in good
condition.
Check that the impact surface of the insertion tool
shank is flat, with no signs of wear.
Make sure that the air inlet and exhaust ports are
free from obstructions.
Check that the flushing hole in the drill steel is not
blocked, and that the flushing air flows through
without obstruction.
Ensure that the fittings are tight and leak-proof.
DANGER
Whipping air hose
A compressed air hose that comes loose can lash
around and cause personal injury or death
Check that the compressed air hose and the
connections are not damaged.
Check that all compressed air connections are
properly attached.
Blow out the air hose
Every day before using the drill, blow out the air
hose to clear it of accumulated dirt and moisture.
Fill the lubricator with oil
Check that the chuck and insertion tool shank are
always covered with a film of oil.
Start and stop
WARNING
Involuntary start
Involuntary start of the machine may cause injury.
Keep your hands away from the start and stop
device until you are ready to start the machine.
Learn how the machine is switched off in the event
of an emergency.
Stop the machine immediately in all cases of
power supply interruption.