Operating pressure
Power
Free speed
Speed under load
Percussion under load
Percussion energy
Volume flow
Drilling capacity in concrete
Drilling capacity in concrete of medium
hardness
Optimum drilling capacity
Drilling in steel with quick-release chuck
Drilling in wood with quick-release chuck
Hydraulic connection machine
Hydraulic connection hose set
Hydraulic fluid
Hydraulic circuit
Oil filtering
Temperature of oil
Viscosity of oil
Shank
Dimensions, L x H x W
Weight (without hoses)
Sound pressure level L
Sound power level L
Vibration
ATEX Classification
Remark: Measurement acc. to
(1)
DIN EN ISO 15744
Remark: Measurement acc. to
(2)
DIN EN ISO 28927-5
The performance specifications are guide values only, they depend basically on the
application, the working pressure and the accessories used.
TECHNICAL SPECIFICATION
(1)
pA
WA
(2)
Before operating
this machine make
sure, that you are familiar
with the operating and
safety instructions.
79915
max. 80 bar
1.2 kW
500 +/- 50 1/min
450 +/- 50 1/min
3400 blows/min
2 J
15- 45 l/ min
ø5-28 mm
ø12 mm= 34 cm³/min = 300 mm/min
ø12-20 mm
ø5-13 mm
ø5-30 mm
SAE PORT N
.8 (3/4x16 UNF – 2 B)
o
Flat-Star A250-OM/OF-1/2"BSP
Hydraulic oil
Open circuit
ISO purity degree 20/18/13
- 34°C to + 82°C
>13 centistokes
SDS Plus
460 x 260 x 102 mm
8.2 kg
92 db(A)
101 db(A)
4.5 m/s²
II 2G Ex h IIB T5 Gb
Measurement uncertainty K: 3 dB (A)
Measurement uncertainty K:1.5 m/s