Models with oscillating handle
Note: Two "O" rings, one 13/16" O.D. and a smaller 3/4" O.D. are packaged loose with this repair kit.
Read following instructions to determine use if necessary, of each.
1/ Turn off water supply.
2/ Loosen set screw securing bonnet.
3/ Remove the following and keep for re-use: - handle
4/ Remove and DISCARD the following:
- existing TEMPUS II cartridge
- nylon spacer
5/ Install new cartridge, (if cartridge shoulder cannot be pushed to
within 1/16" of body, remove cartridge and install cartridge spacer over "O" ring
and re-install). Secure with new capnut.
6/ If metering cartridge cannot be installed into body remove
TOP "O" ring and replace with 13/16" O.D. "O" ring. (Supplied Loose.)
7/ Place nylon spacer & fibre washer over stem and
re-install spring, handle and bonnet.
8/ Secure bonnet with set screw.
9/ Turn on water supply.
10/ If water drips after cartridge shut-off install 3/4" O.D. (packaged separately)
"O" ring over end of metering cartridge against shoulder.
Notes: Cycle times are factory preset 9 to 16 seconds at 50 PSI. For a shorter
cycle time reduce push button/handle travel by changing position of timing
adjustment nuts.
CAUTION: DO NOT OVERTIGHTEN capnut, Tighten to 12 ft-lbs. (Max)
Models with push button
Note: Two "O" rings, one 13/16" O.D. and a smaller 3/4" O.D. are packaged
loose with this repair kit.
Read following instructions to determine use if necessary, of each.
1/ Turn off water supply.
2/ Remove existing TEMPUS II cartridge & push button and discard.
3/ Install new TECK cartridge, (if cartridge shoulder cannot be pushed
to within 1/16" of body, remove cartridge and install cartridge spacer
over "O" ring and re-install). Secure with new capnut.
4/ If metering cartridge cannot be installed into body remove
TOP "O" ring and replace with 13/16" O.D. "O" ring. (Supplied Loose.)
5/ Place new push button onto cartridge and secure with set screw.
6/ Turn on water supply.
7/ If water drips after cartridge shut-off install 3/4" O.D. (packaged separately)
"O" ring over end of metering cartridge against shoulder.
Notes: Cycle times are factory preset 9 to 16 seconds at 50 PSI.
For shorter cycle time reduce push button/handle travel by
changing position of timing adjustment nuts.
CAUTION: DO NOT OVERTIGHTEN capnut, Tighten to 12 ft-lbs. (Max)
Box 5750, 420 Burbrook Place,
London, Ontario, Canada N6A 4L6
Tel. 1-800-567-3300 (ENG.)
Tél. 1-800-265-9425 (FR.)
INSTALLATION SHEET
[Part No. 190010A]
- bonnet
- spring
[Part No. 190009A]
Metering Faucet Body
or
Urinal Valve Body
RETROFIT
Urinal Valve Body
Existing TEMPUS II Cartridge
Nylon Spacer
DISCARD
Urinal Valve Body
New Metering Cartridge
Cartridge
Shoulder
Timing Adjustment Nuts
Top "O" Ring (See 6)
Locate 3/4" O.D. "O" Ring here (See 10)
Cartridge Spacer (See 5)
(Retrofit Kit Only)
Metering Faucet Body
or
Urinal Valve Body
Timing Adjustment Nuts
Cartridge Shoulder
Top "O" Ring (See 4)
Locate 3/4" O.D. "O" Ring here (See 7)
Box 40980, 55 East 111th Street
Indianapolis, Indiana, 46280
Tel. (317) 848-1812
Website: www.deltafaucet.com
Spring
Bonnet
Handle
KEEP FOR USE WITH NEW CARTRIDGE
New Capnut
New Nylon Spacer
Bonnet
Handle
Spring
New Fibre Washer
TEMPUS II Metering Cartridge
Push Button
DISCARD
New Push
Button
New Capnut
New Metering Cartridge
Cartridge Spacer (See 3)
(Retrofit Kit Only)
Part No. 200798 Rev. 1