STORING THE TRANSMITTERS THROUGH
THE SW1 BUTTON
L1 - the LED lights up when the SW1 button is pressed to store
or delete any transmitters
L2 - the LED lights up when the DEV-R2 module receives a code
existing in memory
Storage through L1 LED
1. Press the SW1 button of the DEV-R2 module to be
programmed: the L1 LED lights up
2. Press the button of the transmitter to be stored within
8 seconds
3. The L1 LED restarts: the code has been stored and the
receiver waits for a new code to be stored for 8 seconds
4. Memorise all the transmitters necessary
5. After 8 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
Storage through L2 LED
1. Press the SW1 button of the DEV-R2 module to be
programmed: the L1 LED lights up
2. Press the SW1 button again: L1 LED turns off and L2 LED
turns on
3. Press the button of the transmitter to be stored within
8 seconds
4. The L2 LED restarts: the code has been stored and the
receiver waits for a new code to be stored for 8 seconds
5. Memorise all the transmitters necessary
6. After 8 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
All manuals and user guides at all-guides.com
9
TRANSMITTER STORAGE VIA RADIO
This procedure allows for storage of transmitters without directly
accessing the module.
NOTE: it is necessary to use a remote control previously stored
(TX1) and proceed as follows:
1. Press and hold the P1+P2 buttons on TX1 transmitter for
around 5 seconds
2. Release the button: press the button on the TX2 transmitter
to be stored within 8 seconds
3. Repeat this operation for any other transmitters
4. After 8 seconds without a valid transmission, the led is turned
off and the receiver returns to normal operating mode
MEMORY CLEARING
This procedure enables to clear all the transmitters stored in the
DEV-R2 module.
1. Switch off the DEV-R2 module
2. Hold the button SW1 and at the same time switch on the
DEV-R2 module
3. After 2 seconds, release the button SW1: the motor confirms
successful clearing by moving in both directions for half a
second