ADJUSTING THE ANGLE INDICATOR
If necessary, the position of the angle indicator
can be re-adjusted.
Loosen the screws on the underside of the
miter table attachment (approx. 1/2 turn). Also
loosen the preset angle release button and
locking screw if necessary. Align the saw blade
of the mounted saw with the aid of a protractor
or square to achieve the 0º setting. Tighten the
thumbscrew to secure setting, then securely
tighten the screws on the underside of the table
attachment (Fig. 11).
FIG. 11
ALIGNING SAW BLADE 90º
TO THE MITER TABLE ATTACHMENT
If necessary, the blade can be re-aligned to be
90º to the table. First, loosen the thumbscrew.
Then align the saw blade of the mounted saw
with the aid of a square. Rotate the blade
alignment screw clockwise or counter-
clockwise until you achieve the 90 degree
setting. Then tighten the thumbscrew (Fig. 12).
FIG. 12
BL DE LIGNMENT
SCREW
All manuals and user guides at all-guides.com
The miter table attachment is equipped with a
dust port for dust extraction. To use this
feature, attach a vacuum hose to the dust port,
and then attach opposite end to a shop vacuum
cleaner (Fig. 13).
FIG. 13
NGLE
INDIC TOR
DJUSTMENT
SCREWS
LOCKING
SCREW
-10-
DUST EXTRACTION
DUST
PORT