These instructions apply to the following models:
INDUSTRIAL SLIDER
The INDUSTRIAL SLIDER automations for industrial sliding gates up
to 3500 kg are electromechanical operators which transmit
movement to the leaf by means of a pinion with rack coupled
in an appropriate manner to the sliding gate.
The system is guaranteed to be mechanically locked when the
motor is not in operation so a lock does not need to be installed.
The gear motors have adjustable mechanical clutches to ensure
correct use of the automation. A convenient manual release
device allows the gate to be opened in the event of a power
failure or malfunction. The electronic control unit is incorporated
in the gear motors.
The INDUSTRIAL SLIDER automations have been designed and
built for vehicle access control in industrial areas. Do not use for
any other purpose.
1.
DESCRIPTION AND TECHNICAL SPECIFICATIONS
3
8
9
1) Electronic control unit
2) Casing
3) Electric motor
4) Clutch adjustment screw
5) Door safety sensor
2.
DIMENSIONS
Values are expressed in mm.
INDUSTRIAL SLIDER AUTOMATION
2
5
1
4
6
Fig. 1
7
6) Earthing screw
7) Manual release device
8) Mechanical limit switch with roller
9) Transmission pinion
Fig. 2
Table 1 Technical specifications
Power supply
Power consumption
Reduction ratio
No. of pinion teeth
Nominal torque
Max. thrust
Duty rating
Temperature range
Gear motor weight
Housing protection
Max. gate weight
Gate speed
Max. gate length
Clutch
Casing painting
Control unit
Limit switches
Gear dimensions LxHxD
Electric motor technical specifications
Power supply
Frequency
Current
Power consumption
Motor speed rpm
3.
ELECTRICAL SET-UP
RSTN
380V 5x2,5 mm
RST
220V 4x2,5 mm
1) Operator with control unit
2) Photocells
3) Key switch
4) Flashing light
5) Radio receiver
4.
INSTALLING THE AUTOMATION
4.1.
PRELIMINARY CHECKS
For safe, correct operation of the automation, make sure that the
following requirements are met:
•
The gate's structure must be suitable for automation. Take
special care to ensure that the wheels are large enough to
support the full weight of the gate, that a top runner is
installed and that mechanical limit stops are fitted to prevent
the gate from coming off the runner.
•
The characteristics of the ground must ensure sufficient support
for the foundation plinth.
•
There must be no pipes or electrical cables in the area to be
dug for installing the foundation plinth.
5
ENGLISH
230V 3ph / 400V 3ph + N (+ 6 % - 10 %) 50Hz
800W
1:30
Z12 Module 6
135 Nm
340 daN
60%
-20°C +55°C
70 kg
IP44
3500 kg
11 m/min.
20 m
Twin discs in oil bath
polyester
incorporated
mechanical
see Fig. 2
230V 3ph/400V 3ph + N (+6%-10%)
50 Hz
3.5A / 2 A
750 W
1400
2
2
Fig. 3