UNPACKING
A NYONE using this power inverter must read, understand, and
follow all safety and operation instructions provided in the
product manual. Failure to closely follow these instructions can
result in circumstances leading to property damage, serious
injury, and death.
• Inspect for damage. Carefully inspect the product for any damage that may have occurred
during shipment. If loss or damage is noted, return the product to the retailer.
FEATURES
SHORT-CIRCUIT PROTECTION
The power inverter will shut down if a short circuit occurs.
OVERLOAD PROTECTION
The power inverter will shut down if an overload situation occurs.
THERMAL SHUTDOWN PROTECTION
The power inverter will shut down due to insufficient ventilation or a high temperature
environment.
LOW VOLTAGE SHUTDOWN
The power inverter will shut down if the power source voltage drops below 10.5 +/- 0.3 volts
to avoid damaging the power source.
LOW SHUTDOWN WARNING
Indicates that the power source has dropped to 11.0 +/- 0.5 volts. The power inverter will
continue to operate.
HIGH VOLTAGE SHUTDOWN
The power inverter will shut down if the power source voltage exceeds 15.5 +/- 0.5 volts to
avoid damaging the power inverter.