Télécharger Imprimer la page

V2 City2 Manuel D'instruction page 27

Publicité

Les langues disponibles
  • FR

Les langues disponibles

All manuals and user guides at all-guides.com
PHOTO 2 INPUT
The photocell 2 is active in closing: if it is dimmed during the
closing it stops the gate and inverts the motion. The option CFCh
activates the photocell even when the gate is still: closed gate
means that no impulse has been given, either it is in pause or it has
received a STOP command. In this case through all the time of the
darkening of the photocell the control unit does not receive any com-
mand of activation at any opening / closing cycle.
CFCh the input PHOTO 2 is available: the photocell is active in
no
Ch
The request for a service will be signalled by means of double blinks
during the whole operation cycle.
WARNING: only a qualified staff shall carry out all service operations.
Once the service has been carried out, the relevant service menu
SErv shall be set up again.
City2 will continue signalling the request for a service until such
parameter is not set up.
END OF PROGRAMMING
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory.
no
Si
THE INSERTED DATA HAVE BEEN MEMORIZED: THE CONTROL
UNIT IS READY TO BE USED.
closing and also when the gate is still
the input PHOTO 2 is not available
the input PHOTO 2 is available: the photocell is active
only during the closing
COUNTER VIEWING
Such a menu allows viewing the number of opera-
tion cycles which such automatism carries out and
it also enables the final user to set up a limit
value in order to show him when the actuators
service is required.
tot.
Total number of completed cycles (the
display views in thousands, press DOWN
to view units).
SErv
number of cycles before the next request
for service.
Such a function is disabled by default, by pressing
UP the display will view -01.0, which shows a
1000-cycle countdown after which City2 will show
the final user that a service is required. Such a
number has been rounded off to hundreds and it
can be set up on 1000-step; set up the desired
value, and then press MENU to confirm.
further corrections to carry out: do not quit the
programming
end of programming
25

Publicité

loading

Ce manuel est également adapté pour:

City2-120v