Les langues disponibles

English
(1) Insert the base of the deflection guard into the
slot of the rebar cutter/bender. (Fig. 18)
(2) Open the guard fully by pulling the arms as
shown below until a click is heard. (Fig. 19)
4. How to remove deflection guard
Reverse the installation procedure to remove
the deflection guard.
5. How to use deflection guard
(1) Be sure to install the deflection guard when
bending a rebar whose bending length and
the fixed length are 20" (inside dimensin of
deflection guard) or less (Fig. 20)
(2) Be sure to install the deflection guard when bending a rebar whose bending length
is 20" (inside dimensin of diflection guard) or less and the fixed length is more than
20". In this case, move the arm at the fixed end. (Fig. 21)
Bending
side
20"
Fig. 20
(3) Remove the deflection guard when bending a rebar whose bending length and the
fixed length are more than 20" (inside dimension of the deflection guard).
CAUTION:
G
Set a rebar on the rebar cutter/bender so that the bending length is equal to or shorter
than the fixed length.
6. Bending by eye measurement
Since the unit uses a variable-speed switch, you can bend the rebar to your desired
angle by eye measurement in addition to the dial setting.
(1) Set the setting dial to a larger angle than you desire.
(2) Pull the switch trigger lightly and bend the rebar slowly.
(3) When the rebar is bent to the desired angle, stop pulling the switch. If the bar is still
small of the desired angle, pull the switch again.
(4) Remove the rebar after bending has been finished. Then, pull the switch once more
and return the bending roller to the home position. (Continue pulling the switch
until the bending roller begins reverse rotation.)
20
Fixed
end
20"
Bending
side
20"
Fig. 19
Fixed
end
Arm
20"
Fig. 21