SPECIFICATIONS
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
[var ies with surrounding
temperature]
Sensing Angle . . . . . . Up to 270°
Electrical Load . . . . . . Up to 200 Watt Maximum Incan-
descent [Up to 100 Maximum
each lamp holder].
Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL
MODE
Lamp Modes . . . . . . . Normal, Soft, Flash
Time Delay . . . . . . . . 1, 5, 20 minutes
Replacement lamp . . . T4, 100W maximum G8 halogen
bi-pin 120 VAC
D
B
Timer . . . . Off, 3, 6 hours, Dusk-to-Dawn
®
ual
rite
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
SYMPTOM
Lights will not come on.
Lights come on in daylight.
Lights come on for no ap-
parent reason.
Lights turn off too late in
Dusk-to-Dawn setting
Lights stay on
continuously.
Lights flash on and off.
Lights flash once, then stay
off in Manual Mode.
598-1315-02
All manuals and user guides at all-guides.com
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
1. Light switch is turned off.
2. Light is loose or burned out.
3. Fuse is blown or circuit breaker is turned off.
4. Daylight turn-off is in effect (recheck after dark).
5. Incorrect circuit wiring, if this is a new installation.
6. Re-aim the sensor to cover desired area.
1. Light control may be installed in a relatively dark location.
2. Light control is in Test. (Set control switch to an ON-TIME position).
1. Light control may be sensing small animals or automobile traffic (re-aim sensor).
2. Range is set too high. (Reduce Range).
3. D
B
Timer is on.
®
ual
rite
1. Sensor is in a relatively dark location. (Relocate sensor, or use 3 hr or 6 hr setting.)
1. A lamp is positioned too close to the sensor or pointed at nearby objects that cause heat
to trigger the sensor. (Reposition the lamp away from the sensor or nearby objects).
2. Light control is pointed toward a heat source like an air vent, dryer vent, or brightly-painted
heat-reflective surface. (Reposition sensor. Reduce Range).
3. Light control is in Manual Mode. (Switch to Auto.)
1. Heat or light from the lamps may be turning the light control on and off. (Reposition
the lamps away from the sensor).
2. Heat being reflected from other objects may be affecting the sensor. (Reposition sen-
sor).
3. Light control is in the Test mode and warming up. (Flashing is normal under these
conditions. Turn Boost off.)
4. Light control is in Flash mode. (An initial start-up flashing is normal in this mode. Select
Normal or Soft mode to turn flash mode off).
1. Sensor is detecting its own lights. (Reposition lamps to keep area below the sensor
relatively dark.)
5