OPERATION
• The water flows when a hand is detected 4 cm in front of the sensor.
• The flow stops on-demand when the hand is passed in front of the sensor, or automatically after 1 minute of flow
(security time flow).
• Automatic duty flush every 24 hours after the last use: This duty flush lasts for 60 seconds, and helps to reduce
the risk of Legionella. It prevents water stagnation and bacterial development in the pipe work.
TECHNICAL CHARACTERISTICS
Electrical supply:
• Battery-operated versions (ref. 452300 and 452310):
- 1 Lithium 3V battery is supplied in the box.
- The ambient temperature should be ≥ 5°C to ensure batteries function correctly.
• Mains versions (ref. 452150, 452159, 452565 and 452569):
- 220-240V/50-60 Hz class II (without earth).
- The installation must conform to local Electrical Regulations/Standards and must be installed by a competent,
qualified electrician.
- If the supply cable is damaged, the installer must replace it.
- Install the box, with the cable gland pointing down.
- The IP65 waterproof electronic housing IP65.
- Connect the sensor to the RMB terminal: red wire to the R terminal, shielding braid to the M terminal and white
cable to the B terminal (fig. H).
- To connect the solenoid valve to the electronic unit, the red wire must be connected to the (+) terminal and the
black wire to the (-) terminal.
• Secure the cables in place with a fixed router e.g. a rigid sheath or cable holder.
• Maximum ambient operating temperature: 40°C.
Water supply:
• Maximum pressure: 8 bar, we recommend 1 – 5 bar.
• Maximum recommended temperature: 40°C.
INSTALLATION
• In order to prevent interference from infrared rays do not install the TEMPOMATIC in front of another
TEMPOMATIC or in front of a mirror or other bright surface.
• Do not cut or lengthen the detection cable.
• The arrow embossed behind the solenoid valve corresponds to the flow direction.
THE INSTALLER MUST ENSURE:
• THE SEAL AROUND THE RECESSING HOUSING IS WATERPROOF TO PREVENT ANY INGRESS OF WATER;
• ANY WATER ACCIDENTALLY ENTERING THE RECESSING HOUSING (E.G. CONDENSATION, RUN OFF, LEAKS,
ETC.) HAS AN EXTERNAL DRAINAGE POINT TO PREVENT ANY STAGNATION;
• THE INTEGRITY OF THE SEALS BETWEEN THE STAINLESS STEEL WALL PLATE AND THE WALL
OR THE WALL PLATE AND THE CONTROL AT LEAST ONCE A YEAR, AND MAKE GOOD IF NECESSARY.
If this advice is not followed, water may leak into the wall. DELABIE cannot be held responsible
for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821 821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
All manuals and user guides at all-guides.com
I
EN