INSTALLATION INSTRUCTIONS
GP AND SM6500 SERIES RANGE HOODS
IMPORTANT SAFETY INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
• Use this unit only in the manner intended by the manufacturer. If you
have any questions, contact the manufacturer.
• Before servicing or cleaning unit, switch power off at service panel
and lock service panel to prevent power from being switched on
accidentally.
CAUTION :
For general ventilating only. Do not use to exhaust
hazardous or explosive materials and vapours.
WARNING - TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE:
• Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium setting.
• Always turn hood ON when cooking at high heat or when flambeing
food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
• Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan or filter.
• Use proper pan size. Always use cookware appropriate for the size
of the surface element.
WARNING - TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING* :
• SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS.
If the flames do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
• NEVER PICK UP A FLAMING PAN - you may be burned.
• DO NOT USE WATER, including wet dishcloths or towels - a violent
steam explosion will result.
• Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already
know how to operate it.
2. The fire is small and contained in the area where it started.
3. The fire department is being called.
4. You can fight the fire with your back to an exit.
*Based on "Kitchen Fire Safety Tips" published by NFPA.
VERTICAL OR HORIZONTAL DISCHARGE
USING 3-1/4" (82.6 mm) x 10" (254 mm) DUCT
CUTOUT DIMENSIONS
CL
18"
(457.2 mm)
3 1/4"
12"
(82.6 mm)
(304.8 mm)
(238.1 mm)
1 7/16" (36.5 mm)
1"
(25.4 mm)
(12.7 mm)
7"
ELEC. K.O.
(177.8 mm)
1/2"
(12.7 mm)
1 7/16"
(36.5 mm)
3 1/4"
(82.6 mm)
FIGURE 2
All manuals and user guides at all-guides.com
ROOF CAP
7/8"
(22.2 mm)
ELBOW
EAVE CAP
9 3/8"
(If required)
3
1
/
" (82.6 mm)
4
x 10" (254 mm)
WALL
1/2"
DUCT
CAP
SUPPLIED DUCT
TRANSITION
6"
(152.4 mm)
RANGE
HOOD
INSTALLATION INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
• Installation
work
qualified person(s) in accordance with all applicable codes and
standards - including fire-rated construction codes and standards.
• Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to
prevent
manufacturer's guidelines and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and local code authorities.
• When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
• Ducted
fans
• To
reduce
• To reduce the risk of fire or electrical shock, this
hood
should
speed control device.
WARNING:
To reduce the risk of shock, disconnect power before
servicing.
CAUTION:
To reduce the risk of fire and to properly exhaust air,
be sure to duct air outside. Do not vent exhaust air
into spaces within walls or ceilings or into attics,
crawl spaces or garages.
CUTOUT DIMENSIONS
KITCHEN
CABINET
(27.0 mm)
FIGURE 1
CUTOUT DIMENSIONS
18"
(457.2 mm)
12"
(304.8 mm)
1 7/16" (36.5 mm)
(177.8 mm)
ELEC. K.O.
WALL
1 7/16"
(36.5 mm)
FIGURE 3
READ & SAVE THESE INTRUCTIONS
and
electrical
wiring
backdrafting.
Follow
the
must
always
be
vented
the
risk
of
fire,
use
only
not
be
used
with
an
HORIZONTAL DISCHARGE THROUGH WALL
SUPPLIED
7"
TRANSITION
(177.8 mm)
1 1/16"
3 3/4"
1 7/16"
(95.2 mm)
(36.5 mm)
10 1/4"
(260.4 mm)
REMOVE DAMPER
TRANSITION FOR THIS
INSTALLATION
VERTICAL DISCHARGE
USING 7" (177.8 mm) ROUND DUCT
(TRANSITION NOT INCLUDED)
7/8"
CL
(22.2 mm)
ADJUSTABLE
7" (177.8 mm) DIA.
9 3/8"
ELBOW
(238.1 mm)
4 7/8"
(123.8 mm)
(177.8 mm)
CL
1/2"
ROUND
7"
1" (25.4 mm)
(12.7 mm)
1/2"
(12.7 mm)
DUCT
6"
(152.4 mm)
must
be
done
by
heating
equipment
to
the
outdoors.
metal
ductwork.
range
additional
solid-state
WALL
DUCT
WALL
CAP
RANGE
HOOD
ROOF CAP
ROOF
REMOVE
7"
BOTH 3-1/4"
(82.6 mm) x
8" (203.2 mm)
& 4-1/2"
(114.3 mm) x
8" (203.2 mm)
KNOCKOUTS
FOR 7"
(177.8 mm)
DUCT
RANGE HOOD
30040592D