9. Frost protection
Using the Frost Protection Mode instead of turning
the thermostat OFF completely may protect against
damages due to low temperatures. The room tem-
perature will be maintained around 5 °C.
Turn OFF the thermostat by pressing
Fig. 1.
• Press M Fig.1 for 3 seconds and release.
• Select 01 (00= disabled).
If the temperature is lower than 5 °C the heating
will be turned ON and
will be shown in the
display.
If the temperature is higher than 7 °C the heating
is turned OFF.
Factory setting is 00.
10. Error messages
E1 will be displayed when room sensor failure.
E2 will be displayed when floor sensor failure.
E2 will be read when pressing M Fig. 1 to check
floor temperature.
Any case, all relay output would be turned off.