Mains output: Connect to supply mains power for the next unit.
Mains input: Connect to supply mains power.
DMX output: For DMX512 link,use 3/5-pin XLR plug cable to link the next unit.
DMX input: For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal.
Microphone: For receiving music for the sound active.
Only for remote control:
Connecting with CA-8 to control the unit for Stand by,
Function and Mode function.
Only for wireless receiver: Connecting with CA-9 to control the unit for Stand by,
Function and Mode function.
4.2 Master/Slave Operation
The unit can be linked together in daisy chain as many as you need in master/slave mode to
perform the great built-in pre-programmed lighting shows triggered by music.
In Master/Slave mode refer to the DMX settings below:
Master unit: DMX start address MUST be set to 001. (First DIP switch = ON, all others are
OFF)
Slave units: DMX start address may have any value but NOT 001 (example: set the first 3
DIP switches to ON)
2-Light Show
Dipswitch 10"off" means the unit works normally and "on" means 2-Light show.
In order to
create a great light show, you can set dip switch 10 "on" on any unit that is linking to the
master unit to get contrast movement to the master unit, even if you have two units only.