23. DO NOT STOP THE COMPRESSOR BY PULLING OUT THE PLUG.
24. USE ONLY RECOMMENDED AIR HANDLING PARTS ACCEPTABLE FOR PRESSURE OF NOT LESS THAN 125 PSI (8.6 BAR).
IMPORTANT NOTE:
Extension cable
Use only three-way extension cables that have three-pin connecting plugs and three-pole sockets that accept the compressor plug. Do not use extension cables
that are damaged or squashed. An under rated cable will cause a drop in line voltage resulting in loss of power and overheating. The table shows the correct
size to use depending on the length according to the following parameters (size in [mm2 ] for a cable with maximum length of 20 mt.):
220/230V
1,5mm2
Description of main parts (Pictures A-B )
1. Handle
2. On/off switch
3. Gauge
4. Compressed air outlet
5. Pressure reducer
6. Safety valve
7. Condensate drain
Technical Data
Voltage/Frequency:
Power/Type:
Max. Pressure
Tank capacity:
Max. air flow:
Operating instructions
INSTALLATION
Position the compressor on a flat surface or one with a max. inclination of 10° in a well-ventilated area. If the surface is sloping and smooth, make sure that
the compressor does not move while in operation. If the compressor operates on a shelf or the edge of a stand, ensure that it may not fall off by securing it
appropriately.
STARTING
Check that the mains power matches that indicated on the data-plate the permissible tolerance range is +/-5%.
Fit the plug in the power socket and start the compressor, turning the switch (2) into position "I/ON".
The compressor is fully automatic, and is controlled by the pressure switch, which stops it when tank pressure reaches maximum value and restarts it when it
falls to minimum value. The pressure difference between maximum and minimum values is usually about 2 bar (29 psi).
After connecting the compressor to the power line, load it to maximum pressure and check correct functioning.
Maintenance
Before starting any maintenance jobs on the compressor:
Make sure that the power supply cable is unplugged from the mains
Make sure there's no pressure in the air tank
The compressor generates condensate water which accumulates in the tank.
The condensate in the tank must be drained at least once a week, by opening the drain tap (7) under the tank.
CONDENSATE MUST NOT BE DRAINED INTO THE SEWER OR DISPERSED IN THE ENVIRONMENT.
Troubleshooting
Air leaks
These may depend on the poor seal of some of the pipe fittings within the machine; check all the pipe fittings by wetting them with soapy water.
The compressor fails to start
If the compressor fails to start, check:
- if all the wires are connected properly
- if the compressor is electrically powered (plugged in correctly, circuit breaker tripped, blown fuses).
4
110/120V
2,5mm2
230V-50Hz
1.5Hp/Oilless
8Bar
6Lt
180Lt/min
WWW.NIKOLAOUTOOLS.GR
* The manufacturer reserves the right to make minor changes to product design and technical spec-
ifications without prior notice unless these changes significantly affect the performance and safety of
the products. The parts described / illustrated in the pages of the manual that you hold in your hands
may also concern other models of the manufacturer's product line with similar features and may not be
included in the product you just acquired.
* To ensure the safety and reliability of the product and the warranty validity, all repair, inspection,
repair or replacement work, including maintenance and special adjustments, must only be carried out
by technicians of the authorized service department of the manufacturer.
* Always use the product with the supplied equipment. Operation of the product with non-provided
equipment may cause malfunctions or even serious injury or death. The manufacturer and the importer
shall not be liable for injuries and damages resulting from the use of non-conforming equipment