HYDRALVAC 6000 / HYDRALVAC OXYDROSS
M3285V1 :
To change value of parameters press the
Increase or decrease the value by the
If the
button is not activated during 2 minutes, the fourth line will automatically turn blank.
TROUBLESHOOTING
PROBLEM
CAUSE
Insufficient vacuum
1. The cover is not installed correctly on the gasket.
under the cover
2. The gasket is run‐down.
3. Filters are plugged.
4. Problem on the vacuum pump.
5. Nozzle dia.1.5 is plugged.
MAINTENANCE
Each year :
Drain the vacuum pump
Change the separator cartridge (only HYDRALVAC 6000).
Change filters 'PORAL'.
Change the gasket of the base.
Maintenance kit HYDRALVAC 6000 : 624951
Maintenance kit HYDRALVAC HYDROSS : 625201
MAIN SPARE PARTS
Vacuum pump
Filter
Sheet gasket
EV of line
EV of atmospheric pressure
Pressure sensor
Fuses
MILLENIUM Automate
Power supply 24v cc
12
Program number
button.
or
button. To valid, press the
HYDRALVAC 6000
K04
423032
359006
221146
361364
359792
358221
361557
362375
361741
SOLUTION
1. Place the cover correctly.
2. Change it.
3. Change them.
4. See its technical manual.
5. Clear it.
HYDRALVAC OXYDROSS
K4HV
824224
359006
221146
361364
359792
358221
361557
362375
361741
button.
520499-05