Télécharger Imprimer la page

K2 Pumps SPS05004TPK Notice D'utilisation page 4

Publicité

Les langues disponibles

Les langues disponibles

SPECIFICATIONS
Power supply
Liquid temp. range
Discharge size
Sump basin
NOTE: Do not reduce size of discharge pipe or hose below 1-1/4 in. diameter. If discharge is too small, pump will
overheat and fail prematurely. This pump is designed for use in a residential sump only. Only pump water with this pump.
INSTALLATION
1. Install the pump in sump pit with minimum diameter of 14in.(356mm). The sump depth should be 18 in. (457 mm).
Construct the sump pit of tile, concrete, steel or plastic. Check local codes for approved materials and for proper
installation.
2. Install the pump in a pit so that the switch operating mechanism has maximum possible clearance.
3. The pump should not be installed on clay, earth or sand surfaces. Clean the sump pit of small stones and gravel
which could clog the pump. Keep the pump inlet screen clear.
NOTE: Do not use ordinary pipe joint compound on plastic pipe. Pipe joint compound can attack plastics.
4. Connect 90°elbow to the pump outlet. Install discharge plumbing. Use rigid plastic pipe and wrap threads with
PTFE pipe thread sealant tape. Screw pipe into the pump hand tight plus 1-1/2 turns.
CAUTION: Risk of flooding. Can cause personal injury and/or property damage. If a flexible discharge hose is used,
make sure the pump is secured in the sump to prevent movement. Failure to secure the pump may allow pump
movement, switch interference and prevent the pump from starting or stopping.
5. To reduce motor noise and vibrations, a short length of rubber hose (1-7/8 in. (47.6 mm) I.D., e.g. radiator hose) can
be connected into the discharge line near the pump using suitable clamps.
6. Install an in-line check valve or an in-pump check valve to prevent flow backwards through the pump when the pump
shuts off.
NOTE: If your check valve is not equipped with an air bleed hole to prevent air locking the pump, drill a 1/8 in. (3.2
mm) hole in the discharge pipe just above where the discharge pipe screws into the pump discharge. Be sure the
hole is below the waterline and the check valve to prevent air locks.
7. Power Supply: Pump is designed for 115 V, 60 Hz, operation and requires a minimum 15 amp individual branch
circuit.
4
115V, 60 HZ., 15 Amp Circuit
32°F to 95°F (0°- 35°C)
1-1/4 in. MNPT or 1-1/4 in. FNPT (with adaptor)
Min. 14 in. (356 mm) diameter, 18 in. (457 mm) depth
For Professional Technical Support call 1-844-242-2475

Publicité

loading