Télécharger Imprimer la page

Publicité

EN

TECHNICAL DATA

Minimum dynamic pressure:____________________________________________________0.5 bar
Maximum operational pressure:___________________________________________________5 bar
Recommended operational pressure:____________________________________________1-5 bar
It's recommended to use a pressure reducer in case of
static pressure superior than 5 bar inside the waterpipe.
Maximum hot water temperature:_________________________________________________80°C
INSTALLATION, MAINTENANCE AND PRELIMINARY CHECKING PROCEDURE
In order to get your device work correctly and fine in time, must ensure compliance
with the mode of installation and maintenance described in this booklet. Relying on
a qualified plumber. Make sure that the system is free from all debris and impurities
existing.
INSTALLATION
Fig. 1: Screw the hoses. Screw the tie rod by inserting the fiber gasket.
Fig. 2: Make a hole in the plane (MIN Ø48mm – 1.88 in, MAX Ø55mm - 2.16 in)
Position the body on the surface, passing the hoses and the tie rod inside the hole and
positioning the sealing gasket.
Fig. 3: From below the surface, insert the gasket and the flange in the tie rod, screwing
the nut until it is completely blocked. Screw the reduction into the tie rod by inserting
the fiber gasket.
Fig. 4: Make a hole on the surface Ø30 mm - 1.18 in, position the shower support on the
surface by positioning the seal.
Fig. 5: From under the plane insert the gasket and screw the ring nut until it is
completely blocked.
Fig. 6: Insert the end of the hose through the shower support. Connect the other end to
the showerhead and place it in the shower holder.
Fig. 7: From under the surface, screw the end of the hose to the reduction of the tie rod
until it is completely locked.
After finishing the installation of the tap with the built-in body, turn on the stopcocks
and check that the mixer tap unit operates correctly. Keep the tap pressurized for a few
minutes checking eventual leaks.
CLEANING
In order to get a correct cleaning, exclusiveny wash with soap and water, rewash and dry
with deerskin and a soft cloth. Avoid to use alcohol, solvents, solid or liquid detergents
made by corrosive or acid substances, towel made by synthetic materials, abrasive
sponges, because they could irreversibly alterate the treated surfaces.

Publicité

loading