Temperature Range. Selects the highest temperature in heating mode (18-
− Flow.
EN
EN
FR
−
Supply temperature (only available in installations with Airzone ZBS 10 KOhm
IT
PT
−
Information. This parameter provides information about the system and the
DE
If the zone management is selected, the available parameters are:
− Name. Shows the name of the zone.
− Zone ID. Shows the zone number assigned among the available.
− Linked zones. Shows displays the control outputs associated with the
controller.
− Basic mode. The zones can be set in Basic or Advanced mode. They are set in
− User mode setpoint. This option is used to configure the set point temperature
16
30˚C / 64-86˚F, 30˚C / 86˚F by default) and the lowest temperature in cooling
mode (18-26˚C / 64-78˚F, 18˚C / 64˚F by default). It is also possible to disable
some of the modes.
o
Type of opening (only available in installations with intelligent
damper). Use this parameter to configure the type of opening of the
damper output: All/Nothing or Modulating (by default).
o
Minimum air (only available in installations with intelligent damper
and with the parameter Type of opening configured as modulating).
This allows the access of a minimum air flow in zones where the set-
point temperature has been already reached. It is deactivated by
default.
NTC thermistor). This option allows the system demand to be ignored if the
supply temperature exceeds a certain limit. The selectable heating cut out
temperatures are 38-46-54-62-70˚C / 100-114-129-143-158˚F. By default, the
system will stop heating if the supply temperature reaches 54˚C / 129˚F.
Note: The system will not generate heat until past 4 minutes (minimum) from
the shut of demand.
connected elements.
Advanced mode by default. These are the parameters you can control in basic
mode: On/off, set-point temperature, airflow and operation mode.
of each user mode for each zone:
o
Comfort. Heat: 15 to 30˚C / 59 to 86˚F by default 20˚C / 68˚F. Cool: 18
to 30˚C / 64 to 86˚F, by default 24˚C / 75˚F.
o
Eco. Heat: 15 to 30˚C / 59 to 86˚, by default 19˚C / 66˚F. Cool: 18 to
30˚C / 64 to 86˚F, by default 25˚C / 77˚F.
o
Unoccupied. Heat: 15 to 22˚C / 59 to 72˚F, by default 17˚C / 63˚F.
Cool: 24 to 30˚C / 75 to 86˚F, by default 27˚C / 81˚F.
o
Vacation. Heat: 10 to 16˚C / 50 to 61˚F, by default 10˚C / 50˚F. Cool: