GS030-10;
GS030-11
Model GS031-10
Model GS031-10
Part of
Part of
Sira 12ATEX2169X
Sira 12ATEX2169X
LSI G1P 2J7 CAN
LSI G1P 2J7 CAN
THIS SIDE UP
THIS SIDE UP
GCxxx, GS001, GS002, GS005, GS010, GS020; GS020;
Ignition hazard: "WARNING - POTENTIAL
ELECTROSTATIC CHARGING HAZARD"
FCC
W
ARNING
C
Read the operator's manual.
Test before every use.
Batteries: "C" size lithium 3.6V or alkaline.
T
: the light on the bottom must flicker red
EST
and green when the cable is cycled in and out.
USA:
International:
C
IC:7076A-ICGS050
* This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any
interference received, including interference that
may cause undesired operation.
GS050;
Load Systems
International Inc
IC: 7076A-ICGS000
* This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received,
including interference that may cause undesired
operation.
GCxxx, GS001, GS002, GS005, GS010, GS020;
See manual for details.
Replace with Tadiran TL5930 lithium 3.6V battery. Use
non-corrosive RTV sensor safe silicone only. The use of other
silicones may void the warranty.
International Sales & Service (Houston, USA): 281-664-1330
58
58
Model №: GS050
Anti-Two-Block
Switch
!
C
(888) 819 4355
+1 281 664 1330
C
FCC ID: QVBGS050
Model №: GC012
Load Cell 12 000 lb
Single part line pull capacity
FCC ID: QVBGS000
(ub219)
Étiquette placée à l'intérieur des compartiments
à pile GCxxx, GS001, GS002, GS005, GS010,
GS020 (ATEX et FCC).
L S I I N C .
L S I I N C .
B a t t e r y O p e r a t e d :
B a t t e r y O p e r a t e d :
D Ty p e , L i t h i u m , 3 . 6 V D C
D Ty p e , L i t h i u m , 3 . 6 V D C
C l a s s I , G r. A , B , C & D
C l a s s I , G r. A , B , C & D
E x i a
E x i a
I N T R I S I C A L LY S A F E
I N T R I S I C A L LY S A F E
Te m p e r a t u r e C o d e : T 4
Te m p e r a t u r e C o d e : T 4
M o d e l :
M o d e l :
Plaque d'acier UB223 en inoxydable placée sur
les capteurs 'Intrinsèquement Sécuritaire'.
7.3
Certification Classe 1
7.3
Certification Classe 1
Division 1 et Division 2
Division 1 et Division 2
La certification Classe 1 Division 1 (à Sécurité
Intrinsèque) est disponible pour la plupart des
capteurs
LSI
. Classe 1 Division 2 (non incendiaire)
LSI
est disponible pour les afficheurs GS550 et GS820.
Le certificat CSA #1332949 sur le contrat 215780
est disponible sur demande.
Les normes applicable testée par CSA:
•
CSA C22.2 No. 0.4-M2004 – connexion à la
terre d'équipements électrique
•
CSA C22.2 No. 0-M1991 – requis généraux
selon le code électrique canadien partie II.
•
CSA C22.2 No. 0142-M1987: Équipements de
contrôles en zone dageurese
•
CSA C22.2 No. 157-M1992 - Appareils à
sécurité
intrinsèque
incendiaires pour emplacements dangereux
•
C22.2
No.213-M1987
incendiaires pour utilisation dans les zones
classe 1 division 2
•
UL norme 508 (UL508) – équipements de
contrôle industriels en zones dangeureuses
•
UL norme 913 (UL913) 6ème et 7ème éditions
Appareils intrinsèquement sécuritaires pour
utilisation dans les zones classes I, II, III
division 1, classifiées zones dangeureuses
(Série GS)
•
UL norme 1604 (UL1604) – Équipements
électrique pour utilisation en zones classe I et II,
division 2 ainsi que classe III pour zones
classées dangeureuses.
2 1 5 7 8 0
2 1 5 7 8 0
C
U S
U S
et
appareils
non
–
Appareils
non
Le système GS820