7.1
Insulation test, English - German

Insulation test

Isolationsprüfung
Each set must be insulation tested after having been dismantled.
Make the test when the set has been reassembled and is ready to be returned to
the customer.
Flashovers must not occur during the testing procedure!
Make the insulation test as follows:
Short-circuit the two pins of the mains plug and connect them to one of the
terminals of the insulation tester. Connect the other terminal of the insulation
tester to the chassis pin of the headphone socket.
NOTE!
To avoid damaging the set it is essential that both terminals of the insulation tester
have good contact.
Slowly turn the voltage control of the insulation tester until a voltage of 2.5kV is
obtained. Maintain that voltage for one second, then slowly turn it down again.
Nach der Zerlegung muß bei jedem Gerät eine Isolationsprüfung vorgenommen
werden.
Prüfung vornehmen, wenn das Gerät zusammengebaut und zur Auslieferung an
den Kunden bereit ist.
Während der Prüfung dürfen keine Überschläge auftreten!
Isolationsprüfung folgendermaßen vornehmen:
Beide Stifte des Netzsteckers kurzschließen und mit einer der Klemmen des
Isolationsprüfers verbinden. Andere Klemme des Isolationsprüfers am Masseanschluß
der Kopfhörerbuchse anschließen.
ACHTUNG!
Um Beschädigungen des Geräts zu vermeiden, müssen beide Klemmen des
Isolationsprüfers unbedingt einen einwandfreien Kontakt haben.
Spannungseinstellung des Isolationsprüfers langsam auf eine Spannung von 2,5 kV
erhöhen. Diese Spannung eine Sekunde beibehalten, anschließend langsam
verringern.