Transport And Storage - Diehl Metering WESAN WP Instructions D'installation

Table des Matières

Publicité

WP, WPV, WPV A, WS
1.
Note
This installation guide is intended for trained personnel and therefore
does not include basic working steps.
Changing measuring insert: A seal or sticker must be attached
(between the housing and housing cover) for approval reasons.
The seal on the meter must not be damaged! A damaged seal
immediately invalidates the factory warranty and calibration.
Respect the right choice of the model, the permanent flowrate (Q
temperature and the pressure area.
2.

Transport and storage

ƒ
Water meters are precision devices and must be protected against
impact and vibration!
ƒ
Store meters in a frost-free place.
ƒ
If a risk of frost exists, empty the system and, if necessary, remove
the meter.
3.
Installation instructions (installation position see fig. I)
ƒ
Thoroughly flush out the pipes before installing the meter.
ƒ
If the water is soiled, fit the strainer in the pipe before the meter.
ƒ
Install the meter in a frostproof position at the lowest possible point
of the installation to avoid air accumulating.
ƒ
Install the water meter in the approved installation position.
ƒ
Position the meter with the arrow mark in the correct direction of
water flow.
ƒ
The water meter must be installed in the pipe without mechanical stress.
ƒ
Flange seals must not protrude into the pipe.
ƒ
On completion of installation, fill the pipe slowly to prevent pressure
shocks damaging the measuring insert.
ƒ
The water meter must always be filled full with water.
ƒ
The meter must be protected against pressure shocks in the pipe.
ƒ
The pipe pressure and water temperature must not exceed the values
shown on the type plate.
ƒ
All flow control components (e.g. valves) should be installed after the
meter.
-8-
Deutsch
English
), the
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wesan wpvWesan wpv aWesan ws

Table des Matières