desired room temperature and how to maintain this temperature. In this way, it
provides minimum energy consumption by calculating how long your heating / cooling
unit should work for.
What is the difference?
In non-TPI room thermostats, the heating / cooling unit works and stops continuously
until it exceeds the set temperature value. If the set temperature drops below a certain
amount, the heating / cooling unit will work again. This creates greater temperature
fluctuations and less energy control. TPI Room Thermostats, on the other hand, provide
higher savings and comfort compared to On/Off room thermostats with the
advantages it has.
Heating Mode
Your room thermostat takes the average room temperature of last 40 seconds as
basis. With the TPI algorithm in the product by creating a general temperature map of
your home, it learns how long it takes to reach the desired room temperature and how
this temperature is maintained. Thus, it ensures that the room temperature remains
within a certain range.
TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC
Cooling Mode
Your room thermostat takes the average room temperature of last 40 seconds as
basis. With the TPI algorithm in the product by creating a general temperature map of
your home, it learns how long it takes to reach the desired room temperature and how
this temperature is maintained. Thus, it ensures that the room temperature remains
within a certain range.
TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC