Factory Settings Reset - Imit Silver CR S Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
Temperature sensors which are used in Room Thermostats are highly sensitive. You
may need to calibrate your Room Thermostat if you would like to get the same
temperature values with other thermometers in your living space.
While your device is turned off, press and hold the "On/Off" button for 3 seconds.
Press the "On/Off" button until the "CAL" menu appears. In order to see the desired
temperature, set the temperature difference by pressing the "Temperature Adjustment
Buttons". This value can be arranged between "-8° C" and "+8° C".
In order to save the settings and exit, press the "On/Off" button until the device turns off.
Note: Recommended temperature calibration is "0.0°C".

FACTORY SETTINGS RESET

You can reset your Room Thermostat to its default factory settings. This operation
resets the mode temperature values, calibration setting and heating/cooling modes
settings to factory setting. In order to reset your Room Thermostat to factory setting:
While your device is turned off, press and hold the "On/Off" button for 3 seconds.
Press the "On/Off" button until the "RST" menu appears.
While in the "RST" menu, select the "YS" option by using the "Up" or "Down" buttons and
press the "On/Off" button.
Your device will be turned off and reset to factory settings.
KEY LOCK
In the Room Thermostat there is a key lock function to avoid any unintended contact.
In order to unlock the Room Thermostat's key lock the "On/Off" button should be
pressed for 3 seconds. If buttons on Room Thermostat are not touched for 10 seconds,
key lock will be reactivated.
DAY AND HOUR SETTINGS
While your Room Thermostat is on, keep pressing the "Weekly Program" button for 3
seconds.
At the first screen that appears, hour part will be blinking. You may set the time with the
"Up" and "Down" buttons.
After setting the time, the "Heating & Cooling Option" button needs to be pressed once.
For minute setting, minute part will be blinking. You may set the minute with the "Up"
and "Down" buttons.
After setting the minute, the "Heating & Cooling Option" button needs to be pressed
once to set the day of the week.
Monday has set as the first day of the week and indicated with number "1".
Numbers indicate the following days respectively 2-Tuesday, 3-Wednesday,
4-
Thursday, 5-Friday, 6-Saturday and 7-Sunday
When setting is done, you may exit by pressing the "Weekly Program" button for 3
seconds.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Silver rf s

Table des Matières