Télécharger Imprimer la page

noken FUSION Mode D'emploi page 25

Publicité

Equipment
Action
Press hydromassage
HYDRO
push-button with led
Equipment
Action
Press air massage
AIR
push-button with led
Troubleshooting
Possible cause
Button light OFF and water
Differential switch or magnetothermic OFF
massage OFF
Button light OFF but water
Faulty push-button
massage ON
Incorrect water level
The hydromassage stopped a few
seconds when starting or during
Faulty level sensor
the process
Faulty electrical box
No electricity current at the whirlpool pump
The button light is ON for a few
Problem with the whirpool pump
seconds but the hydromassage
does not work
Problem with the electronical box
Efficiency reduction of the
Jet/vacuum protection cover clogged or dirty
hydromassage
Troubleshooting
Possible cause
Button light OFF, air massage OFF
Diferential switch or magnetothermic off
Button light OFF, air massage ON
Faulty push-button
Defective blower or connections
Button light ON, air massage OFF
Problem with the electronical box
Eficiency reduction of the massage
Jet clogged or dirty
User solution
Connect the differential switch or magnetothermic
-
Fill the bathtub above the starting level
-
-
-
-
-
Clean
User solution
Connect the differential switch or magnetothermic
-
-
-
Clean
Authoritzed technical service
-
Change the push-button
-
Change level sensor
Change the electronical sensor
Check connections and measure the whirlpool pump
input (230 VAC). Change if necessary.
Check connections and measure the whirlpool pump
input (230 VAC)
Check the noise
Change the whirlpool pump (If applicable)
Check connections
Change the electronical box
-
Autoritzet technical service
-
Change the push-button
Check connections and messure the blower input
(230V AC)
Check the noise
Change the blower(if applicable)
Check connections
Change the electronical box
-
25

Publicité

loading