LEAK TEST
Now that the heater is assembled, for your safety you must perform a leak test
of all connections and hoses.
Mix in a vaporizing bottle equal parts of water and soap.
•
Ensure that the heater gas control knob is fully
closed by turning completely clockwise
•
Open the gas supply valve.
•
Apply generously the solution to
all connections and hoses.
If you detect bubbles, there is a leak. Close the gas supply valve completely. Retighten
the leaking connection and repeat leak test process.
If the leak cannot be repaired permanently, close the gas supply valve completely and
contact the retail outlet where you purchased the heater or a qualified gas technician.
A SAFE LOCATION FOR THE HEATER
CAUTION
When objects are left under a heater in operation, they will be subject to radiant heat
and might be damaged.
● The principal application of this heater is to give the comfort of heat to pool and
spa areas, terraces, work areas, etc.
This heater is approved for outdoor use only.
● Provide fresh air ventilation at all times
● Respect minimum clearances to combustibles as shown in figure below.
● Install heater on a leveled, solid and stable ground.
● Do not install in an explosive environment. Keep away from areas from where gas,
vapors or inflammable liquids are stored or used.
● In case of high winds, shut-off completely the heater and the cylinder gas valve.
Remove reflector dome.
● Do not move the heater when hot.
CLEARANCES FROM COMBUSTIBLES
Respect clearances as shown:
-
Sides of reflector : 24 inches
-
Above reflector :
18 inches