TEMPERATURE ADJUSTMENT BUTTONS: Pressing the
3 seconds, after that it will show again to the real water temperature. When it is flashing you can adjust the temperature using the
button.
The default temperature is 35°C (95°F).
Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
ON/OFF BUTTON: After activating the PRCD, press and hold the
panel is activated. Press and hold
CELSIUS/FAHRENHEIT TOGGLE: The temperature can be displayed in either Fahrenheit or Celsius.
WATER FILTER BUTTON: The
FOR SPA EQUIPPED WITH Wi-Fi ONLY
Wi-Fi ACTIVATION: For the Wi-Fi operation instruction, read the spa Wi-Fi instruction leaflet included in the package.
The WATER HEATER rate may change in the conditions below:
• When the outdoor temperature is below 15°C (59°F).
• If the cover is not in position. Always keep the spa cover on when the spa is not in use; it avoids dust contaminating the water and it minimizes heat
loss.
• The water temperature shown on the display may not be correct, if the filtration system is not activated. To read the correct water temperature on the
display, run the filtration system for at least a minute.
• The water temperature as tested by an external thermometer may vary from the temperature as displayed on the spa panel by as much as
approximately 2°C (35.6°F).
WINTER USE INSTRUCTIONS
It is important to follow these suggestions if you are setting up the spa during the winter period. This will prevent any damage to the spa
heater and material of the liner, extending the life of your product drastically.
• If the outdoor temperature is below 10°C (50°F), to avoid any damage to spa liner, keep the package indoors where the temperature is above
15°C (59°F). This will make the spa liner more flexible and easier to set up.
• Open the package and inflate the spa liner using the spa heater in a room where the temperature is above 15°C (59°F).
• Position the spa liner outdoors in the desired position, then connect the spa heater and fill with water. The water temperature used to fill the spa must be
above 6°C (42.8°F), otherwise when you begin to operate with the spa heater, the E03 alarm will appear.
• You can keep the spa on during winter when the temperature is lower than 6°C (42.8°F). The Freeze Shield™ system automatically keeps the water
temperature between 6°C (42.8°F) and 10°C (50°F), and it will prevent the water from freezing.
• If the water temperature is below 6°C (42.8°F), the spa heater must always be on. In this mode, the Freeze Shield™ system can keep the internal
temperature between 6°C (42.8°F) and 10°C (50°F) to prevent damage, such as water freezing in the pipes or the circulation system.
• If any alarms appear on the display, the Freeze Shield™ system isn't working. Be sure to check the status of your spa if the outdoor temperature is
below 6°C (42.8°F). In case of a long-term absence from home when there is a risk of temperatures falling below 6°C (42.8°F), we strongly suggest
disassembling the spa and storing it following the storage procedure.
• Any damage as a result of using the spa in these conditions is the responsibility of the customer. Do not use the spa when the ambient temperature
reaches -10°C (14°F).
HEATING TIME
• To reach 40°C (104°F), the heating duration required is based on the starting water temperature and ambient temperature, the data below is purely for
reference. To display the current water temperature, run the filter system for at least a minute.
Ambient Temperature
10ºC (50ºF)
15ºC (59ºF)
20ºC (68ºF)
25ºC (77ºF)
30ºC (86ºF)
• Be sure to cover the spa with the spa cover whenever the heating function is activated. Leaving the spa uncovered will increase the heating duration
required. When the spa is assembled with water, do not switch off the spa heater if the temperature is lower than 6ºC (42.8°F).
SPA HEATER SPECIFICATION
Power Rate
110-120V AC,
60Hz, Single Phase
12A at 20ºC
button for 2 seconds to turn off all currently activated functions.
button turns the filter pump on and off. The
Water Temperature
10ºC (50ºF)
15ºC (59ºF)
20ºC (68ºF)
25ºC (77ºF)
30ºC (86ºF)
Massage Tube Blower
6.5A
or
button, the display starts to flash showing the set temperature for
button for 2 seconds. The
button turns to red when activated.
Set Temperature
40ºC (104ºF)
40ºC (104ºF)
40ºC (104ºF)
40ºC (104ºF)
40ºC (104ºF)
Heat Element
11.3A at 20ºC
11
button turns to green and the control
Heating Duration
23-40h
18-36h
13-29h
9-20h
7-15h
Water Pump
0.7A
or